Fault Diagnostics (Continued)
Problem/Report
Possible Cause
Suggested Action
Warm Drinks
Insufficient cooling air flow through the
fridge.
Check that the condenser is not blocked.
Check supply to cooling fans (230V AC).
If supply present replace fans.
If supply not present move on to the
compressor. The supply to the fans and the
compressor are linked.
Compressor not running
Check supply to compressor (230V AC).
If supply not present check the Eliwell
fridge controller is operating.
Check for system over heat. Allow the unit
to cool and check for airflow obstructions.
Once the unit has cooled the fridge system
will restart. If the problem persists contact
technical support.
If the Eliwell controller is operating check
the operating parameters are correctly set
and inspect the probes. Replace probes
as necessary.
Eliwell fridge controller not operating.
Check supply to the controller. If present
replace the controller.
If supply is not present check the PCB.
PCB not operating.
Check the fuses on the board and the fuse
in the mains plug. If fuses are ok replace
the PCB.
Fridge failure
If compressor & fan are running and there
is no cooling contact technical support.