628 & 698 Models
16
RESETTING DETECTOR
In the unlikely event of a leak from a Borg & Overström machine the water detector will automatically shut off both
the power and incoming water supply. Please follow the following procedures to reset the detector to regain normal
operation.
LEAKS & REPAIRS
1. Unplug the machine from the electrical supply. Intially the machine must be left unplugged whilst the repair is
being carried out.
2. Identify the cause of the leak and replace any necessary parts. Once this has been carried out thoroughly dry out
the channel in the base of the cooler. The probes should then be removed from their locating positions,
thoroughly dried and placed back into position.
3. Now push the red lever back into its normal position so as to return to operation. The power can now be
switched back on to the cooler and the machine is ready for operation.
4. In the unlikely event that the red lever should trigger once more, then procedures 1 to 3 should be carried out again.
5. Please note that the electical power to the machine, not just within the machine, must be disconnected for at
least 5 seconds to enable the device to reset. A shorter on-off-on cycle time is unlikely to be long enough, and
the machine on/off switch will not cut the power to the device.
In the event of any queries please call Technical Support on 0845 4 50 30 90.
Installation & Operation
This product can only be used in conjunction with a Borg & Overström water
cooler.
Please follow the step-by-step procedures for installation:
1. Please fix the Leak Detector as high as possible within the machine.
Ensure that the red lever has sufficient space to be activated. It is
imperative that the electrical connections are facing upwards and the
water pipe is installed into the base of the Leak Controller and that the
Leak Controller is mounted vertically.
2. The detection probes can now be fixed into their locating holes in the
channel within the base plate.
3. The inlet and outlet connection ports for the water are connected via 1/4”
push fit fittings. The pipe already located within the machine must be
connected to the outport on the machine and the supply feed coming into
the machine must therefore be placed into the inport. Find a connection
plug within the back of the machine where the power supply comes in.
Please part the two sections of this connection plug and plug your Leak
Controller into these two connections. Note: This will only work one way
round (you cannot get it wrong).
4. Your Leak Detector is now ready for operation. Please ensure that the
red lever is in the closed position before plugging in your Borg &
Overström water cooler to the mains supply.
Summary of Contents for 628
Page 1: ...INSTALLATION OPERATION GUIDE 628 698 MODELS ...
Page 3: ...Section1 Technical Manual ...
Page 7: ...Section 2 Technical Manual ...
Page 19: ...Section 3 Technical Manual ...
Page 23: ...Technical Manual Section 4 ...
Page 35: ...Section5 Technical Manual ...
Page 40: ...628 698 Models 40 Borg Overstrom 628 698 Cold Ambient Ambient Electrical Diagram ...
Page 41: ...628 698 Models 41 Borg Overstrom 628 698 Hot Cold Production series No 10 ...
Page 42: ...Technical Manual Section6 ...
Page 47: ...Section7 Technical Manual ...
Page 58: ...Technical Manual Section8 ...
Page 75: ...Notes ...
Page 76: ...Notes ...
Page 77: ...Notes ...
Page 78: ...Notes ...
Page 79: ...Notes ...
Page 80: ...Notes ...