Ventilation
The cooling system is fully automatic. The cooling fan starts with a low speed when the calories
brought out by the electronic system reach a certain level. The ventilation starts his high speed
when the hob is intensively used. The cooling fan reduces his speed and stops automatically when
the electronic circuit is cooled enough.
min
Power
display
min
Keep warm key
Pause/
Recal key
Locking key
On/Off
key
Power selection zone “Slider” (front zone)
Timer
keys
Timer
display
Use of the appliance
Designation
Zero
Booster level
No pan detection
Heat accelerator
Error message
Residual heat
1st Booster
2nd Booster
Keep warm
Stop&Go
Bridge
Display
0.
1…9
U
A
E
H
P
U
II
Description
The heating zone is activated.
Selection of the cooking level.
No pan or inadequate pan.
Automatic cooking.
Electronic failure.
The heating zone is hot.
The 1st Booster is activated.
The 2nd Booster is activated.
Maintain automatically of 42, 70 or 94°C.
The hob is in pause.
2 cooking zones are combined.