66
Installation and Maintenance
Service Manual
1
0
.2 Removal Procedure of Outdoor Unit
Procedure
Steps
1.Remove cable cross plate sub-assy
and valve cover
3.Remove front grille
2.Remove top cover
Remove the screws fixing cable cross plate
sub-assy and then remove the cable cross plate
sub-assy.
Remove the screws fixing valve cover and then
remove the valve cover.
Remove connection screws connecting the
top cover plate with the front panel and the
right side plate,and then remove the top
cover.
Remove connection screws between the
front grille and the front panel. Then remove
the front grille.
top cover
cable cross plate
sub-assy
valve cover
front grille
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
All models except:GWC09AFC-A3DNA1A/O GWC12AFC-A3DNA1A/O
ANOTE: Take GWH12QC-A3DNA6E/O for example.