8.2 Installation Parts-checking
8.3 Selection of Installation Location
8.4 Requirements for Electric Connection
8.5 Installation of Indoor Unit
Air-conditioner
Breaker
capacity
07/09/12K
15A
18K for some model
20A
18/24K for some model
25A
1.Please contact the local agent for installation.
2.Dont use unqualified power cord.
2. Grounding Requirement:
(1)
The air conditioner is first class electric appliance. It must
be properly grounding with specialized grounding device
by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
(2)
The yellow-green wire in air conditioner is grounding wire,
which cant be used for other purposes.
(3)
The grounding resistance should comply with national
electric safety regulations.
(4)
The appliance must be positioned so that the plug is
accessible.
(5)
An all-pole disconnection switch having a contact
separation
of at least 1/8 inch in all poles should be
connected in fixed
wiring.
(6)
Including a
breaker
with suitable capacity, please note
the following table.
Breaker
should
include
magnet
buckle
and heating buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the fuse only
for
protect the circuit)
1. Choosing Installation Iocation
Recommend the installation location to the client and then
confirm it with the client.
2. Install Wall-mounting Frame
(1) Hang the wall-mounting frame on the wall; adjust it in
horizontal position with the level meter and then point out the
screw fixing holes on the wall.
(2) Drill the screw fixing holes on the wall with impact drill (the
specification of drill head should be the same as the plastic
expansion particle) and then fill the plastic expansion particles
2. Indoor Unit:
(1) There should be no obstruction near air inlet and air outlet.
(2) Select a location where the condensation water can be
dispersed easily and wont affect other people.
(3) Select a location which is convenient to connect the
outdoor unit and near the power socket.
(4) Select a location which is out of reach for children.
(5) The location should be able to withstand the weight of
indoor unit and wont increase noise and vibration.
(6) The appliance must be installed 72inch above floor.
(7) Dont install the indoor unit right above the electric
appliance.
(8) Please try your best to keep way from fluorescent lamp.
3. Outdoor Unit:
(1) Select a location where the noise and outflow air emitted by
the outdoor unit will not affect neighborhood.
(2) The location should be well ventilated and away from
strong wind.
(3) The location should be able to withstand the weight of
outdoor unit.
(4) Make sure that the installation follows the requirement of
installation dimension diagram.
(5) Select a location which is out of reach for children and far
away from animals or plants.If it is unavoidable, please add
fence for safety purpose.
Note:
1. Safety Precaution
(1) Must follow the electric safety regulations when installing
the unit.
(2) According to the local safety regulations, use qualified
power supply circuit and
breaker
.
(3) Make sure the power supply matches with the requirement
of air conditioner. Unstable power supply or incorrect wiring
may result in electric shock,fire hazard or malfunction. Please
install proper power supply cables before using the air
conditioner.
(4) Properly connect the live wire, neutral wire and grounding
wire of power socket.
(5) Be sure to cut off the power supply before proceeding any
work related to electricity and safety.
(6) Do not put through the power before finishing installation.
(7) If the supply cord is damaged,it must be replaced by the
manufacturer,its service agent or similarly qualified persons in
order to avoid a hazard.
(8) The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper tube.
(9) The appliance shall be installed in accordance with national
wiring regulations.
1. Basic Requirement:
Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the local dealer:
(1) The place with strong heat sources, vapors, flammable or
explosive gas, or volatile objects spread in the air.
(2) The place with high-frequency devices (such as welding
machine, medical equipment).
(3) The place near coast area.
(4) The place with oil or fumes in the air.
(5) The place with sulfureted gas.
(6) Other places with special circumstances.
(7) Do not use the unit in the immediate surroundings of a
laundry a bath a shower or a swimming pool.
(8) It’s not allowed to be installed on the unstable or motive
base structure(such as truck) or in the corrosive environment
(such as chemical factory).
Check Submittals for
Breaker Sizing
Summary of Contents for brisa BRS09HPJ1IA
Page 4: ...1 1 Summary Part Technical Information Indoor Unit B2 BRS09 24HPJ1IA...
Page 5: ...2 Technical Information BRS09HPJ1OA BRS12HPJ1OA BRS18HPJ1OA BRS24HPJ1OA Outdoor Unit...
Page 29: ...26 6 1 Remote Controller Introduction of...
Page 30: ...27 Technical Information...
Page 31: ...28...
Page 32: ...29 Technical Information...
Page 89: ...86 Installation and Maintenance...
Page 94: ...91 Installation and Maintenance BRS18HPJ1OA BRS24HPJ1OA Note Take heat pump for example...
Page 95: ...92 Installation and Maintenance...
Page 96: ...93 Installation and Maintenance...
Page 97: ...94 Installation and Maintenance...
Page 98: ...95 Installation and Maintenance...