EN
29
Installation
www.bora.com
5.7.4 Exiting the configuration menu
X
X
Twist the knob ring until the display shows
C
.
X
X
Now press the touch surface on the control knob
again for 1 second to exit the configuration menu. The
display goes out and a beep sounds.
X
X
Turn the knob ring to the 12 o’clock position.
0
appears in the display for 10 seconds. The display then
goes out with a beep.
INFO
If no settings are changed in a menu or submenu
option for 2 minutes, the configuration menu is
closed automatically.
5.8 Initial operation
X
X
The appliance can be used for the first time when
installation and configuration of the gas cooktop are
complete.
5.8.1 Using the gas cooktop for the first
time
X
X
Switch the cooking zone on.
The electronic gas regulator will calibrate itself (humming
noises) and then the gas flame will automatically ignite in
the selected cooking zone.
The gas flame will burn steadily and evenly.
5.8.2 Using the gas cooktop with the
cooktop extractor for the first time
X
X
Switch the cooktop extractor to the maximum power
level.
X
X
Switch all cooking zones to the minimum power level.
The electronic gas regulator will calibrate itself (humming
noises) and then the gas flame will automatically ignite in
the selected cooking zone.
The gas flame will burn steadily and evenly (no reignition).
The gas flame will be slightly affected by the cooktop
extractor (airflow) – this is normal.
5.8.3 Faults during initial operation
When operating for the first time or after a prolonged
period without use or when the liquid gas bottles have
been changed, faults are possible:
Q
Q
The burner does not ignite. The control knob emits a
beeping sound and the power level display flashes.
Q
Q
There may be air in the gas pipe.
X
X
Repeat the ignition process via the touch surface on
the control knob.
Q
Q
The burner does not ignite and the cooktop does not
react.
Q
Q
The electronic gas regulator must be recalibrated.
X
X
Using configuration
C 5 0
, reset the gas regulator.
Q
Q
The control knob display shows an error message
(e.g. E001).
X
X
Using configuration
C 5 0
, reset the gas regulator.
5.9 Handover to user
X
X
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and
handling to the user.
X
X
Adhere the supplied nameplate to the back of these
operating and installation instructions.
X
X
Provide the user with the accessories and operating
and installation instructions to be kept in a safe place.