EN
23
Installation
www.bora.com
5.5.3 Sealing the cooktop
X
X
Make sure that no silicone sealant gets under the
cooktop.
1
Fig. 5.18 Silicone sealant for flush installation
[1]
black, heat-resistant silicone sealant
1
Fig. 5.19 Silicone sealant for surface mounting
[1]
black, heat-resistant silicone sealant
5.5.4 Establishing communication
The appliance components are linked by the ribbon cable
provided.
X
X
Create the connection between the cooktop and the
control knobs.
X
X
Create the connection between the cooktop and the
cooktop extractor.
Cooking zone connection
INFO
According to the default settings, the left control
knob operates the front cooking zone and the
right control knob operates the rear cooking zone.
Connection on the control knob
1
Fig. 5.20 Connection on the rear of the control knob
[1]
Connection on the rear of the control knob
Connections on the cooktop
3
2
1
ZONE1 INTERF. COM1 ZONE2
Fig. 5.21 Connections on the cooktop
[1]
Connection of the front cooking zone control knob (zone 1)
[2]
Connection of the automatic extraction system
[3]
Connection of the rear cooking zone control knob (zone 2)
Standard cooking zone connection
5
4
3
2
1
Fig. 5.22 Standard cooking zone connection
[1]
Cooktop
[2]
Rear cooking zone (zone 2)
[3]
Front cooking zone (zone 1)
[4]
Rear cooking zone control knob (zone 2)
[5]
Front cooking zone control knob (zone 1)
X
X
Connect the connection on the back of the left control
knob [5] to the “zone 1” connection on the front of the
cooktop [1].