EN
15
Device description
www.bora.com
4.3.5 Timer functions
There are two different timer functions for each cooking
zone.
Q
Q
t
appears in the control knob display.
INFO
You can set a time range of between 1 and
120 minutes for the timer functions.
Timer function
INFO
The timer function is an automatic cut-off which
automatically switches off a cooking zone which is
in use.
Short-time timer (egg timer)
INFO
The short-time timer requires the cooking zone to
be switched off and works like a conventional egg
timer.
4.3.6 Pause function
The cooking session can be temporarily interrupted (max.
10 minutes).
Q
Q
1 1
appears in the control knob display.
4.4 Safety devices
4.4.1 Safety thermocouple
The gas burners are equipped with a safety thermocouple.
This thermocouple monitors the burner flame when the
gas supply is active. If the burner flame accidentally goes
out, it is automatically reignited by the device. If reignition
is not possible, the gas supply is permanently stopped.
4.4.2 Residual heat display
INFO
While
H
is displayed in the control knob display
(residual heat display), do not touch the cooking
zone or place any heat-sensitive objects on top of
it. Risk of burns and fire!
After switching it off, the cooking zone remains hot.
H
appears in the control knob display (residual heat
display). The display goes out after a sufficient cooling
time (temperature < 60 °C).
4.3.3 Automatic heat up function
The two cooking zones are equipped with an automatic
heat up function that can be switched on and off.
Q
Q
A
appears in front of the power level on the control
knob display.
This function enables the cooking zone to work at full
power for a certain duration after switching on. After this
time, the power level is automatically switched back to
the power level set.
Power level
Cooking duration in min:sec
1
00:40
2
01:00
3
02:00
4
03:00
5
04:20
6
07:00
7
02:00
8
03:00
Tab. 4.4 Overview of the automatic heat up function
4.3.4 Heat retention levels
The heat retention level keeps cooked foods warm.
Q
Q
v
appears in the control knob display.
Q
Q
The maximum duration for the warming function is
limited to 8 hours.
There are three different heat retention levels:
Heat retention level Symbol
Temperature
1
,
40° C
2
:
55° C
#
3
*
70° C
Tab. 4.5 Heat retention levels
INFO
The temperature information on the heat retention
levels can differ as they are influenced by the
cookware, the fill level, the different types of gas
and gas pressures. The temperature information
can also vary due to the influence of the cooktop
extractor.