EN
10
Energy labelling
www.bora.com
3 Energy labelling
Product information according to delegated regulation (EU) no. 65/2014 and regulation (EU) no. 66/2014.
Manufacturer
Model identification
BORA
CKA2
Symbol
Value
Unit
Energy consumption
Annual energy consumption
AEC
hood
28.0
kWh/a
Energy efficiency class
–
A+
–
Energy efficiency index
EEI
hood
37.0
–
Flow volume
Fluid dynamic efficiency
FDE
hood
36.3
–
Fluid dynamic efficiency class
–
A
–
Minimum air flow in normal use
–
239
m³/h
Maximum air flow in normal use
–
559
m³/h
Maximum air flow on intensive or boost setting (power setting)
Q
max
591
m³/h
Measured air flow rate at best efficiency point
Q
BEP
282.3
m³/h
Measured air pressure at best efficiency point
P
BEP
508
Pa
Measured electric power input at best efficiency point
W
BEP
109.7
W
Time increase factor
f
0.7
–
Lighting
Lighting efficiency
LE
hood
*
lx/W
Lighting efficiency class
–
*
–
Nominal power of the lighting system
W
L
*
W
Average illumination of the lighting system on the cooking surface
E
middle
*
lx
Grease filtering
Grease filtering efficiency
GFE
hood
97.7
%
Grease filtering efficiency class
–
A
–
Noise
Airborne acoustical A-weighted sound power emissions at minimum speed
available in normal use
–
45
dB(A) re1pW
Airborne acoustical A-weighted sound power emissions at maximum speed
available in normal use
–
65
dB(A) re1pW
Airborne acoustical A-weighted sound power emissions on intensive or boost
setting (power setting)
–
66
dB(A) re1pW
Sound pressure level at minimum speed available in normal use**
–
32
LpA in dB re 20 µPa
Sound pressure level at maximum speed available in normal use**
–
52
LpA in dB re 20 µPa
Sound pressure level on intensive or boost setting (power setting)**
–
53
LpA in dB re 20 µPa
Power consumption
Power consumption in off mode
P
o
0.25
W
Power consumption in standby mode
P
s
*
W
Tab. 3.1
Energy labelling
* Not applicable to this product.
** Voluntary information
The sound pressure level has been determined from a distance of 1 m (distance-dependent level recording)
on the basis of the sound power level established in EN 60704-2-13.
Summary of Contents for Classic 2.0 Series
Page 56: ...EN 56 Notes www bora com 11 Notes...
Page 57: ...EN 57 Notes www bora com...
Page 59: ......