Installation
www.bora.com
Installation dimensions
b
b
a
a
170
270
100
170
830
535
198
635
515
40
222
89
290
Fig. 6.21 Device dimensions with exhaust air
[a]
Device dimensions without cable extension
[b]
Device dimensions with cable extension
805
490
>50
>900
320
110
b
a
600
700
Fig. 6.22 Kitchen unit dimensions with exhaust air
[a]
Worktop depth from 600 mm
[b]
Worktop depth from 700 mm
6.6 Installing the exhaust air version
(BFIA)
INFO
The state and regional laws and regulations
must be observed with regard to the exhaust
duct design. A sufficient air supply must be
ensured.
6.6.1 Operating the cooktop extractor with
a fireplace that depends on the air in
the room
Fireplaces that depend on the air in the room (e.g. gas,
oil, wood or coal-fired heaters, continuous-flow water
heaters, instantaneous water heaters) draw in air from
the room in which they are installed and release the
exhaust fumes into the outside air via an exhaust system
(e.g. chimney).
If the cooktop extractor is used in exhaust mode, it draws
in air from the room in which it is installed as well as from
neighbouring rooms. If there is insufficient air supply, low
pressure will occur. Toxic gases could be drawn out of the
chimney or extraction ducting and back into the room.
Fig. 6.19 Exhaust air installation – not permitted
Fig. 6.20 Exhaust air installation – correct
X
X
If simultaneously operating both a fireplace and the
cooktop extractor in the same room, ensure that:
Q
Q
the maximum low pressure is 4 Pa (4 x 10–5 bar);
Q
Q
a safety device (e.g. window contact switch, low
pressure warning device) is used to ensure that a
sufficient supply of fresh air is guaranteed;
Q
Q
the exhaust air is not be ducted into a chimney that
is used for exhaust gases of devices operated with
gas or other combustibles;
Q
Q
the installation is checked and approved by an
authorised certified engineer (e.g. heating engineer).