EN
21
Installation
www.bora.com
805
510 - 570
>900
650
>50
119
>25
90
490
>600
90
117
650
675
< R15
133
119
6x Ø5mm
Fig. 6.10 Furniture dimensions for recirculation
> 25
510 - 570
119
> 600
Fig. 6.11 Installation dimensions for recirculation, depth of
worktop 600 mm
Q
Q
The floor unit must have a continuous back wall so
that the recirculation air is not directed into the front
furniture body compartment.
Q
Q
There must be a cut-out in the back wall.
1
2
Fig. 6.8
Height adjustment plates
[1]
Cooktop
[2]
Height adjustment plate
X
X
If applicable, insert the height adjustment plate [2].
X
X
Note down the type designation and build number of
the cooktop (FD number) on the back of this manual.
Both details can be found on the nameplate on the
underside of the cooktop.
6.5 Installing the recirculation
version (BFIU)
INFO
A minimum clearance of 25 mm must be
provided for the vertical return flow aperture.
INFO
A return flow aperture of at least 500 cm
2
must
be provided.
If the cooktop extractor is used exclusively in recirculation
mode, operation with an open fireplace is possible without
any additional safety measures.
Installation dimensions
198
483
830
515
510 - 570
Fig. 6.9
Device dimensions for recirculation