background image

Page 9

BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex

2.7 INSTALLATION OF COOKING UNITS ONTO A PLINTH

2.7.1 WALL SUITE ON A PLINTH

The technical compartment is recommended if the stop cocks, isolators and governors are to be

housed in the range.

Two solutions are possible:

1) The range must include a 400mm cupboard with any type of cooking or neutral top possible,

except induction.

2) A Technical compartment at the end of the range (250mm wide) with neutral top (access panel

in the end).

Toque Blanche

Grande Carte

Length A

N

1 400 + 

N

2 800 + 

N

3 1200, 

ETC

N

1 400 + 

N

2 800 + 

N

3 1200, 

ETC

Length B

710

900

Length C

360

550

Length D

210

400

Length E

100

290

Summary of Contents for P072825

Page 1: ...rsonnel approved by the manufacturer and in accordance with current regulations and standards If any modifications are made the manufacturer can accept no responsibility whatsoever These appliances must be used in a well ventilated area Read the notice carefully before installation The unit must be kept on its base for handling until it is in it s final location N 390 268 9 ...

Page 2: ... identification plate 4 2 Installation General features 5 2 1 General requirements 5 2 2 Handling 5 2 3 Unpacking 5 2 4 Access to components behind the front panel 5 2 5 to 2 7 Installation 7 3 Installation connection 12 3 1 Electrical connection 12 3 2 Water connection 12 3 3 Drain connection 13 4 Electrical circuits 14 5 Hydraulic circuits 16 6 Other spare parts 17 7 Emergency spare parts 18 ...

Page 3: ...t 1200 Width 500 Depth 840 WEIGHT KG 40 ELECTRICITY Voltage I Max P kw 230 V 3a c Three phase 230V E 15 1 6 400 V 3Na c Three phase 400V N E 8 7 6 HOT WATER Pressure Min Max 250 600 kPa or 2 5 6 bar Flexible connection 12 17mm Ø DRAIN 18 mm Ø Compression Connection 18 mm pipe CONSTRUCTION Casing Stainless 18 10 Facia Stainless 18 10 Well Stainless 18 10 APPLIANCE TYPE Free standing against a wall ...

Page 4: ...dth 500 Depth 1030 WEIGHT KG 43 ELECTRICITY Voltage I Max P kw 230 V 3a c Three phase 230V E 15 1 6 400 V 3Na c Three phase 400V N E 8 7 6 HOT WATER Pressure Min Max 250 600 kPa or 2 5 6 bar Flexible connection 12 17mm Ø DRAIN 18 mm Ø Compression Connection 18 mm pipe CONSTRUCTION Casing Stainless 18 10 Facia Stainless 18 10 Well Stainless 18 10 APPLIANCE TYPE Free standing against a wall or other...

Page 5: ...dex B INSTALLATION MANUAL 1 IDENTIFICATION PLATE The identification plates are fixed on the inside of the cupboard door See diagram below In any correspondence about your equipment please quote The model number Model The serial number Fab Nr The date Date Location of the identification plate Identification plate ...

Page 6: ...pliances should ideally be against a wall The latter must be of non combustible materials or if not should be covered with an appropriate material good insulator non combustible 2 2 HANDLING The appliance should be handled with specialised lifting equipment only If the appliance is to be transported this must be done on its original pallet and it must not be stacked in any circumstance If the appl...

Page 7: ...rew and remove the 2 M5 X 16 screws under the fascia Remove front to do so lift front 1 then pull the bottom edge outwards and downwards 2 b Access to electrical components Remove the 2 fixing screws from the top left and right of the control rack Swivel control rack outwards For re assembly reverse the above operations ...

Page 8: ...ront to the underframe with HM 5 x 16mm nuts and bolts 2 washers either inside when the appliance design makes this possible cupboard or from underneath Connect the units to each other 1 at the rear inside the vent again with 5 x 16mm fixings irrespective of the type of equipment 2 at front inside the facia after removing the front of the appliance see section Use HM5 x 16mm bolts 5mm Ø washers fo...

Page 9: ...using HM 5 x 16 bolts for all types of appliance 2 at the front behind the facia see section before Use HM5 x 16mm nuts and bolts 5mm Ø washers to connect cooking units together having removed the M5 captive nut from one of the 2 appliances from the screw side using a screwdriver 3 behind legs using pliers a Position pliers against the fold b Hand tighten as far as possible c Finish tightening wit...

Page 10: ...ks isolators and governors are to be housed in the range Two solutions are possible 1 The range must include a 400mm cupboard with any type of cooking or neutral top possible except induction 2 A Technical compartment at the end of the range 250mm wide with neutral top access panel in the end Toque Blanche Grande Carte Length A N1 400 N2 800 N3 1200 ETC N1 400 N2 800 N3 1200 ETC Length B 710 900 L...

Page 11: ...s are to be housed in the range Two solutions are possible 1 The range must include a 400mm cupboard with any type of cooking or neutral top possible except induction 2 A Technical compartment at the end of the range 250mm wide with neutral top access panel in the end Toque Blanche Grande Carte Length A N1 400 N2 800 N3 1200 ETC N1 400 N2 800 N3 1200 ETC Length B 1420 1800 Length C 720 1100 Length...

Page 12: ... enabling frames to be made to requisite lengths Sheet steel templates are delivered with the stainless steel frames enabling sub assemblies to be positioned and fastened together quickly and accurately Adjust level using adjusting screws provided see diagram above Assemble appliances onto base follow procedure Connect gas electricity and water and check for leaks Fasten ventilation covers to the ...

Page 13: ... indicated below Voltage Cable 380 415 4 x 2 5 mm2 220 240 4 x 4 mm2 Provide suitable multipolar isolator with a contact opening distance of at least 3 mm The installation must comply with current electrical regulations France NFC 15 100 The appliance must be earthed The various electric appliances must also be earth bonded every metal part on the same voltage via the terminal provided located nex...

Page 14: ...C so t he use of PVC is not recommended IMPORTANT As part of the general protection against water network pollution DO NOT CONNECT THE APPLIANCE DIRECTLY TO DRAIN In order to avoid any waste water entering the cooking cell an air break must be installed BETWEEN the appliance and the external drain The drain should be trpped to avoid adours Recommended method ...

Page 15: ...T CIDELCEM GRANDE CUISINE Siége social Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY Cedex 4 ELECTRICAL COIRCUITS 4 1 CONTROL DIAGRAM 4 2 POWER DIAGRAM 230V Three phase 4 3 POWER DIAGRAM 400V Three phase ...

Page 16: ...cial Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY Cedex 4 4 PARTS LIST Ref Designation Quantity Code As Regulator 1 301 200 Fr Three pole thermostat 1 301 055 Hr Indicator 1 308 334 Kr Contactor 1 300 697 Rc Immersion heaters 1 303 122 ...

Page 17: ...dex 5 HYDRAULIC CIRCUITS 5 1 DIAGRAM OF HOT WATER INLET 5 2 PARTS LIST REF DESIGNATION CHARACTERISTICS CODE 1 Handle 138 184 2 Seals 366 369 3 Tap head inch 313 052 4 Tap Body 381 237 5 Spout 313 136 6 Hexagon lock nut 3 8 317 879 7 Brass olive 10 317 877 8 Olive nut 10 318 317 878 9 Water inlet flexible 316 140 ...

Page 18: ...FOOT complete 384 575 384 575 5 LABEL 308 931 308 931 6 WATER INLET KNOB 138 184 138 184 7 CONTROL KNOB 13 28 43 13 28 43 CONTROL KNOB GASKET 366 369 366 369 CUPBOARD DOOR Left door Right door 13 05 64 13 05 65 13 05 64 13 05 65 8 CUPBOARD DOOR MAGNET ALL MODELS 384 110 384 110 9 BASKETS 386 166 386 166 10 FILTER GRILL 39 854M 39 797M 11 BASKET SUPPORT PLATE 39 792 39 792 12 SPOUT 313 136 313 136 ...

Page 19: ...es Lumière Z I Mitry Compans 77292 MITRY MORY Cedex 7 EMERGENCY SPARE PARTS CODE DESIGNATION Toque Blanche Grande Carte IMMERSION HEATERS 303 122 303 122 CONTROL KNOB 13 28 43 13 28 43 CONTROL KNOB GASKET 366 369 366 369 DRAIN TAP CIM 205 MP 3 4 3 4 313 056 313 056 ...