3. INSTALLATION: CONNECTIONS
3.1 ELECTRICAL CONNECTION
Earth bonding point
Whatever the model the electrical connection is at the rear.
- Remove the cover
- Feed cable through cable gland and tighten
- Connect up wires
- Connect earth to bonding point provided.
- Replace cover.
IMPORTANT: Only use power supply cables of H07 RNF type with section as indicated below:
Voltage
Cable
380 / 415
4 x 2.5 mm
2
220 / 240
4 x 4 mm
2
Provide suitable multipolar isolator (with a contact opening distance of at least 3 mm).
The installation must comply with current electrical regulations (France NFC 15.100).
The appliance must be earthed. The various electric appliances must also be earth bonded (every
metal part on the same voltage) via the terminal provided located next to connection cord-grip.
The manufacturer can not be held responsible in case of failure to heed these instructions.
3.2 WATER CONNECTION
- Hot water.
- Pressure min 2.5 bar, max 6 bar.
- Flexible connection 12/17
∅
- Provide a local stop cock.
3.3 DRAIN CONNECTION