11
※
ATTENTION
When you change the parameters , be sure to confirm
「
」
at the display, then
press
「◎」
key to complete the setting.
7-(G): Memory clear mode
Memory clear function resets the memory contents stored in the controller to the
default. (All of soldering iron tip temperature and parameters are rewritten to the
default.) Setting procedures are as follows.
①
Insert a thin bar into the reset switch hole at the front face and keep pushing the
internal switch slightly.
②
Stop pushing the switch when the display shows
「
」
in blinking.
③
iress
「▽」
key to start the memory clear function.
④
The display shows
「
」
while the memory clear function is working.
⑤
「
」
blinks at the display. iress
「◎」
key again, and the buzzer starts to
beep 3 times to return to the operation mode.
※
ATTENTION
Be sure to confirm
「
」
at the display, then press
「◎」
key to complete the
setting.