Before proceeding to connecting
the kiln please make sure that
power supply is OFF
Power supply: The phases are connected to the copper bridge of
the relays.
The copper bridges the contacts 2 / T1, 4 / T2, 6 / T3 of the relay.
Depending on the type of furnace, the two phases are connected in
red insulators, and the third phase in a copper relay truss.
Attention: The controller power cable is also connected to contact 2
/ T1.
Neutral: Attaches to the red insulator
Grounding: Attaches to the yellow screw at the base of the panel
The lower ring is electrically connected to the electrical panel
(upper ring) with an industrial type plug.
There is a terminal on the electrical panel to connect the
thermocouple. ATTENTION to the polarity of the cables
Η type kilns (1300C):
White cable connects to ( - ) contact
Red cable connects to ( + ) contact
L type kilns (1200C):
Green cable connects to ( - ) contact
Red cable connects to ( + ) contact