Main display shows the segment final
temperature.
This can be altered with the
▲
&
▼
keys.
The soak temperature indicator on the
mimic panel will flash (
)
When the desired temperature is set press button
►
Main display shows the soak time in
hours:minutes.
This can be altered in the range 00:00
(no soak) to 99:59 with the
▲
&
▼
keys.
The soak time indicator on the mimic
panel will flash (
►
)
When the desired soak time is set press button
►
The next push of the
►
key increments the segment
number digit and small, segment display will show
number “2” which indicates the second segment of
the selected program.
Follow this steps to enter as many segments as you need.
When all required segments are entered you must mark the end of
the program.
To do that, push the
►
key to proceed to the next segment.
Small, segment display will show the next segment number
Press
▼
key until END is displayed.
21