12.2.2
0x1001/0 Error Register
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x1001
0
Error Register
Unsigned 8
ro
No
0
Object 0x1001/0 is the error register for internal errors of the frequency inverter.
The status error-free (0x1001/0 = 0) or error exists (0x1001/0
≠
0) is displayed.
Detailed information about the current device fault can be checked VPlus with pa-
rameter
Actual Error
259 and 260 via EtherCAT
®
(see chapter 16.4 “Fault messag-
es”).
Also the emergency message contains additional information, which can be evaluat-
ed by the PLC (see chapters 11.5 “Emergency Function” and 12.5.2 “0x603F/0 Error
Object 0x1001/0
7
6
5
4
3
2
1
0 Bit
0
General error
1
Current
2
Voltage
3
Temperature
4
Communication error
5
Device profile-dependent error
6
Reserved
7
Manufacturer-dependent error
42
CM-EtherCAT
07/13