background image

General Safety Information

 

This manual contains important information about 

the assembly, operation and maintenance of this 
heater. 
General safety information is presented in these 
first few pages and is also located throughout the 
manual. 

Keep this manual for future reference and to educate 

new users of this product. This manual should be read in 
conjunction with the labeling on the product. 

Safety precautions are essential when any mechan- 

ical or propane fueled equipment is involved. These 
precautions are necessary when using, storing, and 
servicing. Using this equipment with the respect and 
caution demanded will reduce the possibilities of 
personal injury or property damage. 

The following symbols shown below are used ex- 

tensively throughout this manual. Always pay 
attention to these precautions, as they are essential 
when using any mechanical or propane fueled 
equipment. 

DANGER indicates an imminently hazardous 
situation which, if not avoided, will result in death or 
serious injury. 

WARNING indicates an imminently hazardous 
situation which, if not avoided, could result in death 
or serious injury. 

CAUTION indicates an imminently hazardous 

situation which, if not avoided, may result in minor or 
moderate personal injury, or property damage. 

We cannot foresee every use which may be made 
of our heaters. 
Check with your local fire safety authority if you have 
questions about heaters use. 
Other standards govern the use of fuel gasses and 
heat producing products for specific uses. Your local 
authorities can advise you about these. 

Failure to comply with the precations and instructions 
provided with this heater can result in death, serious 
bodily injury and property loss or damage from 
hazards of fire, explosion, burn, asphyxiation, and/or 
carbon monoxide poisoning. 
Only persons who can understand and follow the 
instructions should use or service this heater. 

This product is fueled by propane gas. Propane gas is 

invisible, odorless, and flammable. An odorrant is nor- 
mally added to help detect leaks and can be described 
as a “rotten egg” smell. The odorant can fade over time 
so leaking gas is not always detectable by smell alone.  

Propane gas is heavier than air and leaking propane 

will sink to the lowest level possible. It can ignite by 
ignition sources including matches, lighters, sparks or 
open flames of any kind many feet away from the origin- 
al leak. Use only propane gas set up for vapor with draw. 

Propane gas should be stored or used in compliance 

with local ordinances and codes or with ANSI/NFPA 58. 
Turn off propane when not in use. 

EXPLOSION-FIRE HA

Z

ARD 

Keep solid combustibles, such as building 

materials, paper or cardboard, a safe 
distance away from the heater as recom- 
mended by the instructions. 

Provide adequate clearances around air 

openings into the combustion chamber.  

Never use the heater in spaces which do or 

may contain volatile or airborne combustibles, 
or products such as gasoline, solvents, paint 
thinner, dust particles or unknown chemicals.  

During operation, this product can be a 

source of ignition. Keep heater area clear 
and free from combustible materials, 
gasoline, paint thinner, cleaning solvents 
and other flammable vapors and liquids. Do 
not use heater in area with high dust 
content. Minimum heater clearances from 
combustible material: two(2) feet from the 
sides & two(2) feet from the top. 

2

Summary of Contents for 67937

Page 1: ...nguish any open flames 3 If odor continues keep away from the appliance and immediately call your gas supplier or fire department WARNING For Outdoor Use Only WARNING Improper installation adjustment...

Page 2: ...the precations and instructions provided with this heater can result in death serious bodily injury and property loss or damage from hazards of fire explosion burn asphyxiation and or carbon monoxide...

Page 3: ...tery eyes headaches dizziness fatigue and possibly death You can t see it and you can t smell it It s an in visible killer If these symptoms are present during operation of this product get fresh air...

Page 4: ...hose should be inspected for spiders spider webs or other insects Check the heater immediately if any of the following exists 1 There is smell of gas 2 The heater is not effective enough 3 The burner...

Page 5: ...3 F Upper Combination 1 G Glass Tube Ring 1 Pre assembled H Door 1 I M5x12 screw 6 Attached into the upper supporter J Tank supporter 1 K Wing Screw 1 L M6 Nut 4 Attached into the tank supporter M Wa...

Page 6: ...cted before use and at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that the control compartment burners and circulating air passag...

Page 7: ...esh guards D into the upper Supporter hook Ensure the mess guard is in the correct position 5 1 Caution 5 2 Step 3 Put the glass tube C into the glass tube ring G 3 1 2 2 Step 4 Put the upper combinat...

Page 8: ...marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for Cylinder Spheres Tubes for transportation of Dangerous Goods Commissio...

Page 9: ...to close the gas supply on the gas cylinder See Figure 3 Screw Regulator Coupling clockwise by hand only Make sure it is fastened See Figure 3 The cylinder connection device is CGA No 791 Connection W...

Page 10: ...ible materials gasoline and other flammable vapors and liquids Don t obstruct the flow of combustion and ventilation air Keep the ventilation openings of cylinder enclosure free and clear from debris...

Page 11: ...garage or any other enclosed area This appliance may be installed with shelter no more inclusive than 1 With walls on all sides but with no overhead cover 2 Within a partial enclosure which includes...

Page 12: ...L BOND TOLL FREE 1 866 771 BOND 2663 OR TO BETTER EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US customer service bondmfg com OR VISIT OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT www bondmfg com BOND MANU...

Page 13: ...ara Uso Exterior ADVERTENCIA La instalaci n ajuste alteraci n reparaci n o mantenimiento incorrectos podr an causar da os materiales lesiones o la muerte Lea atentamente las instrucciones de instalaci...

Page 14: ...con tiraje El gas propano debe almacenarse o usarse en cumplimiento de las ordenanzas y c digos locales o de la norma ANSI NFPA 58 Cuando no use el aparato desconecte la alimentaci n de gas propano N...

Page 15: ...o gripe ojos lacrimosos dolores de cabeza mareos fatiga y posiblemente la muerte No se lo puede ver y no se lo puede oler Es un asesino invisible Si aparecen estos s ntomas mientras este producto est...

Page 16: ...de inmediato en cu alquiera de los siguientes casos 1 Si hay olor a gas 2 Si el calentador no es del todo efectivo 3 Si el quemador hace un ruido detonador durante el funcionamiento un leve sonido det...

Page 17: ...3 F Combinaci n superior 1 G 1 pr assembl e H Puerta 1 I Tornillo M5 x 12 6 Adosado al soporte superior J Soporte de tanque 1 K Tornillo de mariposa 1 L Tuerca M6 4 Adosado al soporte de tanque M Aran...

Page 18: ...e seguridad ESTE APARATO ES S LO PARA USO EXTERIOR 1 Este aparato no debe instalarse ni usarse en el interior dentro de edificios garajes ni otros sectores confinados 2 NO colocar ni apoyar art culos...

Page 19: ...drio para asegurar que los tres orificios coincidan y use tornillos del Paso 2 para ajustarlos Paso 5 Arme las tres protecciones de malla D en el gancho del soporte superior Precauci n Aseg rese de qu...

Page 20: ...o debe estar construido y marcado de acuerdo con las especificaciones para cilindros de GPL del Departamento de Transporte DOT o con la Norma de Cilindros Esferas y Tubos para el Transporte de Art cul...

Page 21: ...ano Revise que quede ajustado Ver la Figura 3 Su Calentador de Patio ha sido sometido en f brica a pruebas de fugas en todas las conexiones Para re visar la conexi n del regulador cilindro Ver la Figu...

Page 22: ...ci n LOW BAJA 7 Para tener m ximo calor gire la perilla de control a la posici n HIGH ALTA 8 Para apagar el calentador gire la perilla de control a la posici n OFF APAGADO 9 Despu s de usarlo cierre l...

Page 23: ...a la posici n OFF Guarde el calentador en posici n vertical en un rea protegida del clima lluvia aguanieve granizo nieve y viento Si lo desea tape el calentador para proteger sus superficies exteriore...

Page 24: ...oqueado Presi n de gas es baja Falta de presi n de gas Fuga de gas en la l nea Termocupla est mal Connexion l che Limpie la suciedad Coloque la luz piloto en la posici n correcta y vuelva a intentarlo...

Reviews: