Instruction Manual for F1300/1600 Mud Pump
21
Fig.15
(1)
Filter (2) Oil distributor (3) Oil line (3A) Spray nozzle (4) Main bearing oil line (4A) Oil distributor
(5)Pressure gauge (6) Relief valve (7) Oil trough (8) Oil tube (9) Lubrication pump
A pressure relief valve (6) is mounted to the oil distributor (2) to prevent excess pressure from
damaging oil pump and drive. The relief valve is preset at 0.27Mpa (40 PSI) and must be tighten (to
prevent adjusted pressure change).
When installing the internally mounted oil pump (9 Fig .15), position pump so that the back face of
the drive gear is flush and parallel with the edge of the main gear, and gear teeth have 0.60~0.90mm
clearance.