page 18
Rev. A, 03/04
Flydat Operator's manual
Initial Start-up
Prior to putting the
into operation, make sure that all
the sensor lines and the supply cable are connected correctly.
Consult the wiring diagram and the chapter about the electric
connections for the particular type of engine.
Until all the connections are checked, do not supply the
with voltage.
With adequate voltage and correctly connected supply,
the background illumination must glow, and
the readings are indicated on the
If any of the temperature sensors or the pressure sensor /in
a 4-stroke engine/ is not connected, three dashes [---] will
show on the display instead of the measured value.
FLY
FLY
FLY
dat
dat
dat
.
c
c
Reaction at start
After connecting the unit on power, it will perform an autotest.
With no errors detected, the logo shows on the display.
First, the display will show the logo, then the date and time
in UTC.
Then the firmware version and the units of temperature (°C/°F)
and pressure (Bar/PSI) are shown. At showing the firmware
version, the alarm output is activated for 1 second.
If the message "SERVICE" is shown after the date and time,
it means that one of the measured quantities has been exceeded.
After pushing the button on the panel or the external button
connected to the pin 7 on the backside of the instrument,
the
will show you which quantity has been exceeded.
f the information on the date and time is
incorrect or if there is "Err" instead of the
month, it means that the internal battery does
not have sufficient capacity. In this case,
contact a service, where the battery will be
replaced.
FLY
dat
NOTE:
I
Operation
®
11
Section