![Bomag BPR 70/70 D Operating And Maintenance Instructions Manual Download Page 86](http://html1.mh-extra.com/html/bomag/bpr-70-70-d/bpr-70-70-d_operating-and-maintenance-instructions-manual_2785506086.webp)
1.
Loosen screw (3) on the rocker arm.
2.
Adjust the screw (2), until the feeler gauge (1) can be
inserted and pulled out with a barely noticeable resistance
after the hexagon nut (3) has been tightened.
1.
Install the valve cover with a new seal and tighten the screws
evenly.
2.
After a short test run check the valve cover for leaks.
8.9.3 Changing engine oil and oil filter element
NOTICE!
Danger of engine damage!
–
Change the oil only with the engine at oper-
ating temperature.
–
Use only oil of the permitted specification
Chapter 8.3.1 „Engine oil“ on page 72
–
Chapter 8.4 „List of fuels and
Adjusting the valve clearance
Fig. 82
Final work
Fig. 83
Maintenance – Annually / every 250 operating hours
BPR 70/70 D
86