![Bomag BPR 45/55 D Operating Instructions Manual Download Page 63](http://html1.mh-extra.com/html/bomag/bpr-45-55-d/bpr-45-55-d_operating-instructions-manual_2785504063.webp)
Trouble shooting
BOMAG
63
BPR 45/55 D, BPR 55/65 D
Fig. 78
l
Join the plus poles on external battery and
starter battery with the jump wire (Fig. 78).
l
Use the second jump start cable to connect
the negative poles on external battery and
starter battery.
l
Start the engine as described in the chapter
“Starting the engine”.
l
When the engine is running remove the jump
start cable from the two negative poles first
and from the positive poles after.
Note
i
This work sequence is necessary to avoid short
circuit caused by contact between positive and
negative cables.
l
Close the hood again and ´fasten it with bolts.
7.3
Fuses
Danger
!
Fire hazard!
Do not use fuses with higher ampere ratings
and do not bridge fuses.
Caution
!
Always cover the fuse with the protective cov-
er.
Fig. 79
Fuse (25 A) (Fig. 79).
Caution
!
Machines with Economizer
1
are protected by
an additional fuse (5 A).
1
Optional equipment
Summary of Contents for BPR 45/55 D
Page 2: ......
Page 7: ...BOMAG 7 BPR 45 55 D BPR 55 65 D 2 Technical Data...
Page 13: ...BOMAG 13 BPR 45 55 D BPR 55 65 D 3 Safety regulations...
Page 19: ...BOMAG 19 BPR 45 55 D BPR 55 65 D 4 Indicators and Controls...
Page 23: ...BOMAG 23 BPR 45 55 D BPR 55 65 D 5 Operation...
Page 34: ...Operation BOMAG 34 BPR 45 55 D BPR 55 65 D...
Page 35: ...BOMAG 35 BPR 45 55 D BPR 55 65 D 6 Maintenance...
Page 42: ...Maintenance BOMAG 42 BPR 45 55 D BPR 55 65 D...
Page 52: ...Maintenance every 6 months BOMAG 52 BPR 45 55 D BPR 55 65 D...
Page 61: ...BOMAG 61 BPR 45 55 D BPR 55 65 D 7 Trouble shooting...
Page 67: ...BOMAG 67 BPR 45 55 D BPR 55 65 D 8 Disposal...
Page 69: ......
Page 70: ......