Trouble shooting
BOMAG
62
BPR 45/55 D, BPR 55/65 D
7.1
General notes
Please observe strictly the safety regulations
in the corresponding section of these operat-
ing and maintenance instructions.
Malfunctions are frequently caused by incorrect
operation of the machine or insufficient mainte-
nance. Whenever a fault occurs you should there-
fore thoroughly read these instruction on correct
operation and maintenance.
If you cannot locate the cause of a fault or rectify it
yourself by following the trouble shooting chart,
you should contact our customer service depart-
ment.
7.2
Starting with jump wires
Note
i
Choose this type of starting if the starter battery is
flat and the machine cannot be started manually
with the recoil starter.
Caution
!
A wrong connection will cause severe damage
in the electric system.
The auxiliary battery must have the same volt-
age as the starter battery.
Fig. 77
l
Loosen the hood fasteners (1) on both sides
and remove the fasteners (2) from both sides
(Fig. 77).
l
Fold the hood back.
l
Remove the battery holder and take off the vi-
bration damping mat.
l
Check insulation mats, brackets and screw
connections, replace if necessary.
Summary of Contents for BPR 45/55 D
Page 2: ......
Page 7: ...BOMAG 7 BPR 45 55 D BPR 55 65 D 2 Technical Data...
Page 13: ...BOMAG 13 BPR 45 55 D BPR 55 65 D 3 Safety regulations...
Page 19: ...BOMAG 19 BPR 45 55 D BPR 55 65 D 4 Indicators and Controls...
Page 23: ...BOMAG 23 BPR 45 55 D BPR 55 65 D 5 Operation...
Page 34: ...Operation BOMAG 34 BPR 45 55 D BPR 55 65 D...
Page 35: ...BOMAG 35 BPR 45 55 D BPR 55 65 D 6 Maintenance...
Page 42: ...Maintenance BOMAG 42 BPR 45 55 D BPR 55 65 D...
Page 52: ...Maintenance every 6 months BOMAG 52 BPR 45 55 D BPR 55 65 D...
Page 61: ...BOMAG 61 BPR 45 55 D BPR 55 65 D 7 Trouble shooting...
Page 67: ...BOMAG 67 BPR 45 55 D BPR 55 65 D 8 Disposal...
Page 69: ......
Page 70: ......