XC 061-AAM.02-MANUAL Rev.03
11
7.3) Make sure the cover of the container is closed correctly (3) to prevent liquid from spur-
ting out in the work phase.
7.4) Connect the head to the pump using a ½” union and high pressure hose [see max.
pressure punched on hose].
Install a safety cock between the head and the supply pump, as explained in chapter 04
section 4.6 4.7.
7.5) Make sure the materials of the head components are compatible with the chemical
specifi cations of the fl uids used.
7.6) Make sure the technical specifi cations, fl ow rate and pressure of the head (page 8) are
compatible with the specifi cations of the pump installed on the system.
7.7) Only in these conditions is the head in the ideal working position, simultaneously having
all the necessary safety requirements.
7.8) The head is set for the specifi cations indicated on page 8 of this manual. If these para-
meters vary, please contact the manufacturer.
Breakages or problems due to parameters that fail to comply with the specifi cations
will not be accepted under warranty.
(07-XC061A-01-EN)
Fig. 7.0
1
3
2
RETE