During installation and commissioning, comply with the indications in Chapter 04
of the General Safety Standards in this Manual. If the aforesaid indications are not
complied with, the Manufacturer shall not be held liable.
See the Technical Data Chapter in the Manual for the pump/head connection and
fastening.
Before switching on, it is advisable to fl ush the system to get rid of any waste or
impurities.
Any breakage or problem due to waste and/or impurities is not covered by the
warranty.
It is advisable to install a 60 micron fi lter between the head and the pump assem-
bly.
Install a safety valve on the head delivery, set at the maximum pressure indicated
on the rotating head or in the Technical Data Chapter in this Manual.
N.B. Do not turn the nozzle holder by hand
IMPORTANT: The head is calibrated with the specifi cations required in the order.
If there are any changes to these parameters, please contact the Manufacturer.
Any breakages or problems due to parameters that do not conform with specifi cations, shall
not be covered by the warranty.
(07-AQM-00-EN)
7) INSTALLATION AND COMMISSIONING (WARNINGS)
SW 060-CF.09-MANUAL Rev.00
13