16
13.
How to make RS422 Daisy Chain multiple camera connection with RS422 standard serial port controller:
PELCO P/D Keyboard RS485 Connection
NOTE: Use RS422 ports for RS485 connection. Only use TX+ and TX- for RS485 connection.
•
Set RS422 control method on Bottom Dip Switch.
•
Set Baud Rate on Bottom Dip Switch to the same as Baud Rate setting on the keyboard you are using.
•
Set the camera ID on OSD menu by remote controller
•
Reboot the camera by turning it Off/On after the Bottom Dip Switch has been set up correctly.
•
Use PELCO P/D compatible keyboard.
•
Use preset 95# on the keyboard to bring up/exit camera OSD menu.
•
Use joystick and Button “OPEN” or “CLOSE” to navigate OSD menu.
•
To operate keyboard, please refer to the user manual of the keyboard you are using.