S2000-IK Rev.02
Addressable Volumetric PIR Motion Detector
OPERATING AND INSTALLATION MANUAL
GENERAL
S2000-IK Revision 02 Addressable Volumetric Passive Infrared (PIR) Motion Detector (hereinafter referred to as the
detector) is designed to detect intrusion into the protected premises with sending alarms to the connected polling loop
controller S2000-KDL or S2000-KDL-2I via its two-wire multiplex addressable polling loop (PL).
The detector is intended to operate as a part of an Orion fire and intrusion alarm system.
The detector features volumetric detection zone providing pet immunity for animals up to 20 kg.
The detector is immune against lighting and radio frequency interference.
KEY FEATURES
Dual-element pyro-electric infrared sensor
High-density coverage offering high probability of detecting an intruder
Protected against insects entering to the pyro-electric infrared sensors
Sabotage-resistant zones just beneath the detector prevents unauthorized access to the detector
Digital signal processing
Powered via the multiplex addressable polling loop of a PL controller
Supports DPLS_v2.51 protocol
SPECIFICATIONS
Detection Zone
Volumetric (see Figure 1)
Detection Range
10 m
Input Voltage
From the PL controller
Consumed Current
0.5 mA max w/o indication
Horizontal Field-of-View
90
°
Operating Temperatures
−
30 to +50°C
Relative Humidity
95% at 25°C, non-condensing
Ingress Protection Rating
IP41
Overall Dimensions (H x W x D)
105 mm
×
75 mm
×
56 mm max
Weight
0.1 kg max
Mounting Height
2.3 meters
MOUNTING LOCATION CONSIDERATIONS
The detector is intended to be used indoors. Considering a
location to mount the detector, please take into account that the
detection zone must not be obscured by any non-transparent
objects such as curtains, houseplants, cabinets, room dividers,
etc. as well as by glass or mesh partitions.
Do not locate the detector where it can be exposed to false alarm
sources such as windows, air conditioners, heaters, radiators, etc.
Wires of the multiplex addressable polling loop should be located
away from high-voltage electric cables.
The detector allows wall or corner mounting at a height of 2.3 m
above the floor. This provides the detection range at least 10
meters. The detection pattern is shown in Figure 1.
Figure 1: S2000-IK Rev.02 Detection Pattern