DESIGN 

The  essential  parts  of  the  DIP-31 detector  are  as  follows (see  Figure 1):  the  detector  base  (Position 1) with  guiding  grooves  (Position 2), two  light 

emitting  indicators  (Position 3),  the  printed  circuit  board  and  the  sensing  chamber  (Position 4),  the  detector  body  (Position 5),  the  detector  cover 
(Position 6), the sensing chamber cover (Position 7), and the screen (Position 8). 

 

 

 

 

 

1 -  

Base 

2 -  

Guiding grooves 

3 -  

LED Indicators 

4 -  

Sensing Chamber with PCB 

5 -  

Detector Body 

6 -  

Detector Cover 

7 -  

Sensing Chamber Cover 

8 -  

Screen 

 

 

 

 

Figure 1 

5

 

MOUNTING AND DETACHMENT 

5.1

 

The detector is to be mounted to the surface of bearing structures using its base (see Figure 2). To install the detector base, drill two holes into the 

surface according to the drilling pattern in Figure 2 and attach the base by means of screws and wall plugs or tapping screws. 
5.2

 

To  install  the  detector  onto  fire  resistant  tiles  of  suspended  ceiling,  use  MK-2  or  MK-3  mounting  kit  for  attaching  the  detector  base  (Figure 3, 

Position 1). Make a mounting hole for the mounting kit according to the marking (Figure 3). 
5.3

 

Until installation works are completed, the sensing chamber of the detector should be covered by the protection cover provided (Figure 3, Position 3). 

 

 

Figure 2 

Figure 3 

5.4

 

To protect the detector against unauthorized removing or to provide secure attachment in the presence of vibrations

,

 lock the detector by doing the 

following. 

Prior  to  installing  the  detector  base,  detach  the  key  (Figure 4,  Position 3)  from  it  and  cut  out  the  rib  (Figure 4,  Position 1)  of  the  locking  click 

(Figure 4, Position 2). 

 

Figure 4 

Summary of Contents for IP 212-31 DIP-31

Page 1: ...ensitivity dB m 0 05 to 0 2 2 2 Rated power voltage V 24 2 3 Consumed current In the quiescent mode uA 140 max In the fire alarm mode mA 10 max 2 4 Internal resistance of the detector in the Fire Alarm mode at the current value 8 mA 2 6 kOhm max 2 mA 4 5 kOhm max 2 5 Start up time s 40 max 2 6 Operating temperature range С Minus 10 through 55 2 7 Relative air humidity Up to 93 at 40 С 2 8 Enclosur...

Page 2: ... holes into the surface according to the drilling pattern in Figure 2 and attach the base by means of screws and wall plugs or tapping screws 5 2 To install the detector onto fire resistant tiles of suspended ceiling use MK 2 or MK 3 mounting kit for attaching the detector base Figure 3 Position 1 Make a mounting hole for the mounting kit according to the marking Figure 3 5 3 Until installation wo...

Page 3: ...ured levels of sensing chamber signal are 75 of the fire condition level FIRE ALARM Light steadily CONTAMINATED CHAMBER Three flashes every 6 s if the signal level has slowly reached 75 percent of the maximum contamination level Drift compensation is performed every 24 hours FAULT Four flashes spaced 200 ms apart every 6 s if the measuring function of the detector is out of order 7 TESTING 7 1 App...

Page 4: ...mitted to the following address NVP BOLID 4 Pionerskaya Str Korolyov Moscow Region 141070 Russia Tel fax 7 495 775 71 55 PBX E mail info bolid ru 8 7 In case of any issue related to use of the product please contact the technical support 7 495 775 71 55 or e mail support bolid ru 9 TRANSPORTING STORAGE DISPOSAL 9 1 The detectors in a transport container are to be transported by any type of covered...

Reviews: