background image

                                                                                  

 
 

 

 

 

 

              

 

 

                     

 

 

 

Models: 

SEAP-12-800 & SEAP-24-1K0 

 

OPERATION  AND  INSTALLATION  MANUAL 

  

 

                            

 

 
Contents  

 

Page 1   

Contents  

Page 2   

Introduction and General  

  Information 

Page 3   

Warranty  

Page 4    

Pre Installation Information  

  Electrical 

Requirements 

 

Page 5   

Installation / AC Wiring 

Page 6   

DC Wiring 

Page 7   

Start Up Procedure 

Page 8   

Controls and Display 
Load Sense Feature and Adjustment  

Page 9   

Adjusting Load Sensitivity  

  Troubleshooting 

Page 10   

How long will my battery last? 

Page 11   

Technical Data 

Page 12   

Mounting Specifications 

 
 
 

Solar Energy Australia Pty Ltd

  

ACN 081 639 038 

 

Sydney:

         4 Beaumont Road. Mt Kuring Gai   NSW   2080 Tel 02 9457 2277 Fax 02 9457 2255 

Melbourne

: 1/15 Nicole Close, North Bayswater,  VIC    3153 Tel 03 9761 5877 Fax 03 9761 7789 

Email:   

[email protected]

           Web site 

www.solaraustralia.com.au

 

 
 
 

Introduction and General Information 

BOLERO

 

High Performance Sinewave 

Inverter 

Summary of Contents for SEAP-12-800

Page 1: ...ture and Adjustment Page 9 Adjusting Load Sensitivity Troubleshooting Page 10 How long will my battery last Page 11 Technical Data Page 12 Mounting Specifications Solar Energy Australia Pty Ltd ACN 08...

Page 2: ...and or service please do not hesitate to contact us to discuss your thoughts Remember As soon as your Solar Energy Australia inverter has been installed please complete and return your warranty card...

Page 3: ...are strictly adhered to Failure to do so will void your warranty Units which are to be permanently used within 1km of the coast should have the marine version of our product this will help to avoid co...

Page 4: ...Ah Ampere Hours This is the amount of energy a battery can store In theory this means that a 200 Ah battery could supply 1 Amp for 200 hours Alternatively if an appliance draws 2 Amps for 4 hrs then...

Page 5: ...solid surface capable of withstanding temperatures of 60 C Allow a cooling space of at least 200mm all around the inverter Placing the inverter in a cupboard or small enclosure may reduce the availabl...

Page 6: ...y a short distance from the inverter in order to obtain best results but not closer than 500mm A battery fuse must be installed no closer than 500mm from the battery to protect all wiring connected to...

Page 7: ...n specifications b Ensure the DC circuit breaker is set to the OFF down position c Plug in the AC connector but do not switch ON d Switch DC circuit breaker to the ON up position e If all is well the...

Page 8: ...the internal temperature has been reduced to a safe level Load Sense Feature and Adjustment Your Bolero inverter features a Standby circuit for automatic load sensing which allows the inverter to rema...

Page 9: ...the amount of AC load on the inverter Inverter shuts down due to Over Temperature Your inverter will safely provide the output power as described in the technical data section in the conditions speci...

Page 10: ...xample a 16 inch TV 67 Watts running on 130AH battery Note Use a figure of 20 if your battery voltage is 24V DC Only 50 of the batteries capacity will be used to allow it to recover How can I tell if...

Page 11: ...no load AC ON 38A 34A DC Current draw at full continuous load 81A 49A DC Current draw maximum 250 160A Efficiency 10 of load 92 91 Efficiency 50 of load 92 92 Efficiency 90 of load 87 88 Peak Efficie...

Page 12: ...Solar Energy Australia Doc No SPN 1601A Rev0803 Page 12 Bolero Manual 243 mm 229mm...