background image

                                                                                  

 
 

 

 

Solar Energy Australia  

 

              

 

 

 
Doc No SPN-1601A     Rev0803 

 

 

 

         Page  11 

Bolero Manual 

DC Low voltage cutout 

9.0-10.5V 

18-21V 

DC High voltage cutout 

16V 

32V 

AC Output power @ 30°C Continuous  

800watts 

1000watts 

                                           30 minutes 

960watts 

1200watts 

                                           60 seconds 

                1600watts 

             2000watts 

                                           5 seconds 

2400watts 

3000watts 

AC Output Voltage 

240v +/ 2% 

AC Output Frequency 

50Hz +/- .5% 

Total Harmonic Distortion 

< 2% 

Maximum AC output current (Short Circuit) 

8A 

11A 

Reset after Short Circuit 

       Every 60 Seconds 

 

DC Current draw in Standby 

50mA 

DC Current draw no load, AC ON 

.38A 

.34A 

DC Current draw at full continuous load 

81A 

49A 

DC Current draw maximum 

250 

160A 

Efficiency @ 10% of load 

92% 

91% 

Efficiency @ 50% of load 

92% 

92% 

Efficiency @ 90% of load 

87% 

88% 

Peak Efficiency 

94% 

Stand-by Adjustment 

4-40watts 

AC Output Connection 

10A GPO or hardwired via three terminal junction box 

DC Output Connection 

1.4metres, 35mm² flexible cables with 10mm lugs 

Fan Control 

ON @ 55° C, OFF @ 45° C,  or ON if power exceeds 800watts 
for 24v model, 640watts for 12v 

Operating Range 

-25°C  

to +50°C

 

Safety Standards 

AS3000 Safety    AS.NZS61558-1.2000 Tfx 

Radio Interference Standard 

AS/NZS2064-1997 

Warranty 

2 years 

Packed Weight 

14kgs 

Dimensions in mm when wall mounted 

364 high x 264 wide x 124 deep 

 

 

 

 

                                   

 

 
 
 
 
 

                       

                                  

 

Summary of Contents for SEAP-12-800

Page 1: ...ture and Adjustment Page 9 Adjusting Load Sensitivity Troubleshooting Page 10 How long will my battery last Page 11 Technical Data Page 12 Mounting Specifications Solar Energy Australia Pty Ltd ACN 08...

Page 2: ...and or service please do not hesitate to contact us to discuss your thoughts Remember As soon as your Solar Energy Australia inverter has been installed please complete and return your warranty card...

Page 3: ...are strictly adhered to Failure to do so will void your warranty Units which are to be permanently used within 1km of the coast should have the marine version of our product this will help to avoid co...

Page 4: ...Ah Ampere Hours This is the amount of energy a battery can store In theory this means that a 200 Ah battery could supply 1 Amp for 200 hours Alternatively if an appliance draws 2 Amps for 4 hrs then...

Page 5: ...solid surface capable of withstanding temperatures of 60 C Allow a cooling space of at least 200mm all around the inverter Placing the inverter in a cupboard or small enclosure may reduce the availabl...

Page 6: ...y a short distance from the inverter in order to obtain best results but not closer than 500mm A battery fuse must be installed no closer than 500mm from the battery to protect all wiring connected to...

Page 7: ...n specifications b Ensure the DC circuit breaker is set to the OFF down position c Plug in the AC connector but do not switch ON d Switch DC circuit breaker to the ON up position e If all is well the...

Page 8: ...the internal temperature has been reduced to a safe level Load Sense Feature and Adjustment Your Bolero inverter features a Standby circuit for automatic load sensing which allows the inverter to rema...

Page 9: ...the amount of AC load on the inverter Inverter shuts down due to Over Temperature Your inverter will safely provide the output power as described in the technical data section in the conditions speci...

Page 10: ...xample a 16 inch TV 67 Watts running on 130AH battery Note Use a figure of 20 if your battery voltage is 24V DC Only 50 of the batteries capacity will be used to allow it to recover How can I tell if...

Page 11: ...no load AC ON 38A 34A DC Current draw at full continuous load 81A 49A DC Current draw maximum 250 160A Efficiency 10 of load 92 91 Efficiency 50 of load 92 92 Efficiency 90 of load 87 88 Peak Efficie...

Page 12: ...Solar Energy Australia Doc No SPN 1601A Rev0803 Page 12 Bolero Manual 243 mm 229mm...

Reviews: