background image

                                                                                  

 
 

 

 

Solar Energy Australia  

 

              

 

 

 
Doc No SPN-1601A     Rev0803 

 

 

 

         Page  5 

Bolero Manual 

• 

Do Not Connect 240V AC or any other power source to the 240V output of the inverter as this may cause irreparable damage 

to the inverter. 

• 

If you need to switch from Inverter to Generator or Shore Power it is absolutely critical that you install a double-pole “Break 

before Make” changeover switch, switching both active and neutral between the inverter and the incoming AC supply.  A 

manual switch is preferred. 

 

 
 

 

Installation 

 
The following steps should be completed in the order shown in this section. 

 

1. 

Unpacking & Mounting 

a) 

Unpack your inverter from its shipping container and inspect the unit for any obvious transit damage.  Report any 

concerns immediately to your supplier. Please keep original packaging in case it is required for re-transport at a later date. 

b) 

Mount the inverter to a suitable surface, paying close attention to the mounting requirements set out below. 

• 

Select a site that is dry and free of salt or moisture-laden air, dust, exhaust or battery gases and access to any rodents. 

• 

Never

 mount the inverter directly above the batteries. 

• 

Mount the inverter as close to the batteries as possible, but no closer than 500mm, mounting should be on a solid surface 

capable of withstanding temperatures of 60°C. 

• 

Allow a cooling space of at least 200mm all around the inverter. Placing the inverter in a cupboard or small enclosure 

may reduce the available output power. The installation site should not be susceptible to temperatures in excess  50

0

C.

 

 

2.

 

AC Wiring 

Important: All AC wiring must comply with relevant Australian and local standards, and be performed by a licensed 

electrician to satisfy warranty requirements and conditions. 

a)  Connect active, neutral and earth to a 10 amp 3 pin male AC plug top. Due to the use of a large transformer, max galvanic 

isolation is provided between the input and output. This means that the Bolero is compatible with M.E.N installations. 

 

b)  It is possible to permanently hard wire the output of the Bolero, this is done by:

 

 

Firstly ensuring all DC inputs are disconnected. 

 

Use a small knife to remove the plastic buttons on the AC outlet. 

 

Unscrew and disconnect the AC outlet. 

 

Using the screws provided attach a Clipsal  559-3 slimline junction box. 

 

Connect the three AC wires to the junction box and secure cover. 

 

 

Warning:

  Please read these instructions thoroughly before commencing installation. Installation should be performed by a 

competent professional electrical / renewable energy installer, as dangerous voltage can be present.  

All relevant Australian 

Standards must be strictly followed.  A licensed Electrician must carry out all AC wiring. 

Summary of Contents for SEAP-12-800

Page 1: ...ture and Adjustment Page 9 Adjusting Load Sensitivity Troubleshooting Page 10 How long will my battery last Page 11 Technical Data Page 12 Mounting Specifications Solar Energy Australia Pty Ltd ACN 08...

Page 2: ...and or service please do not hesitate to contact us to discuss your thoughts Remember As soon as your Solar Energy Australia inverter has been installed please complete and return your warranty card...

Page 3: ...are strictly adhered to Failure to do so will void your warranty Units which are to be permanently used within 1km of the coast should have the marine version of our product this will help to avoid co...

Page 4: ...Ah Ampere Hours This is the amount of energy a battery can store In theory this means that a 200 Ah battery could supply 1 Amp for 200 hours Alternatively if an appliance draws 2 Amps for 4 hrs then...

Page 5: ...solid surface capable of withstanding temperatures of 60 C Allow a cooling space of at least 200mm all around the inverter Placing the inverter in a cupboard or small enclosure may reduce the availabl...

Page 6: ...y a short distance from the inverter in order to obtain best results but not closer than 500mm A battery fuse must be installed no closer than 500mm from the battery to protect all wiring connected to...

Page 7: ...n specifications b Ensure the DC circuit breaker is set to the OFF down position c Plug in the AC connector but do not switch ON d Switch DC circuit breaker to the ON up position e If all is well the...

Page 8: ...the internal temperature has been reduced to a safe level Load Sense Feature and Adjustment Your Bolero inverter features a Standby circuit for automatic load sensing which allows the inverter to rema...

Page 9: ...the amount of AC load on the inverter Inverter shuts down due to Over Temperature Your inverter will safely provide the output power as described in the technical data section in the conditions speci...

Page 10: ...xample a 16 inch TV 67 Watts running on 130AH battery Note Use a figure of 20 if your battery voltage is 24V DC Only 50 of the batteries capacity will be used to allow it to recover How can I tell if...

Page 11: ...no load AC ON 38A 34A DC Current draw at full continuous load 81A 49A DC Current draw maximum 250 160A Efficiency 10 of load 92 91 Efficiency 50 of load 92 92 Efficiency 90 of load 87 88 Peak Efficie...

Page 12: ...Solar Energy Australia Doc No SPN 1601A Rev0803 Page 12 Bolero Manual 243 mm 229mm...