![Bogen Nyquist NQ-S1810CT-G2 Configuration Manual Download Page 18](http://html.mh-extra.com/html/bogen/nyquist-nq-s1810ct-g2/nyquist-nq-s1810ct-g2_configuration-manual_2784495018.webp)
16
Setting the Channel Level
The Channel Level control is a vertical slider that is adjusted in 1-dB increments and con
-
trols the output level for the channel. The Channel Levels can range from -60 to 12 dB. If
you place the mouse over the slider, the numerical value of the level appears.
Adjusting Volume Levels
The vertical slider control can be used to adjust the channel’s output level in 1-dB incre
-
ments between -60 and +12 dB. The overall adjusted output level of the channel signal
can be viewed on the
OUT
VU meter, marked in 2-dB increments between -60 and 0 dB.
Tip:
For best results, use the vertical slider to adjust the input level until you have a strong signal (i.e.,
within the green and yellow areas on the meter), then adjust the final output levels using the DSP Outputs
controls.
To adjust the channel volume level:
1
On the appliance Web UI’s main page, select
DSP
.
2
Use the channel’s slider to adjust the volume level.
Knob Adjustments
Many DSP controls use knobs to adjust one or more settings. The value of a knob can be
adjusted in one of two ways:
1
Click the knob control, hold the mouse button down, and drag the mouse up or down
to increase or decrease the value.
2
Double-click the knob, type a value into the resulting popup, and click the Save but
-
ton.
Table 7. DSP Features
Intercom Tuning
Allows you to specify settings used in intercom calls.
Presets
Allows you to use preset DSP settings for the selected
speaker type.