Bogen Nyquist NQ-S1810CT-G2 Configuration Manual Download Page 17

15

Setting DSP Parameters

When you select DSP from the appliance’s web UI, the DSP page appears.

From this page, you can set parameters for DSP, which is a form of processing that uses 

digital data to simulate characteristics found in analog circuits. With DSP, you can alter 

analog signals, such as audio signals, that have been converted to a digital format.
You can also select 

Save Settings to Server

 to back up all configuration settings to the 

Nyquist server.
The DSP page allows you to adjust the signal level for the Output channel, as well as view

-

ing level indicators for both the input and output signals. Selecting the DSP Features 

button (hamburger menu above the OUT signal indicator) displays a menu that allows 

you to access DSP features, as described in the following table.

Figure 7. DSP Page

Summary of Contents for Nyquist NQ-S1810CT-G2

Page 1: ...VoIP Speaker Configuration Guide NQ S1810CT G2 NQ S1810WT G2 2021 2022 Bogen Communications LLC All rights reserved 740 00121B 220518 ...

Page 2: ...irmware 4 Network Settings Tab Parameters 6 Configuration Settings Tab Parameters 9 Standalone Operation Configuration Settings 11 Setting DSP Parameters 15 Setting the Channel Level 16 Adjusting Volume Levels 16 Knob Adjustments 16 Intercom Tuning 17 Presets 18 Accessing Log Files 20 ...

Page 3: ...g existing network Power over Ethernet PoE ports They also have a Form C relay for controlling third party devices These VoIP speakers enable ease of placement wherever needed within a facility A short press of the appliance s Reset button reboots the device If you press the Reset button for 10 seconds the appliance returns to the factory default configuration settings Returning to the default con...

Page 4: ... that you want to configure and then select the Link icon 2 At the Nyquist Appliance Login page enter username and password and then select Login The default username is admin the default password is bogen The dashboard for the selected appliance appears Using the Dashboard The dashboard displays the following fields Note Do not use third party Chrome browser extensions with the Nyquist user inter...

Page 5: ...al setting on subsequent calls To make permanent adjustments change the station spe cific cut level settings on the Nyquist System Controller The value can be adjusted between 42 and 0 dB Table 2 Appliance Dashboard Buttons Dashboard Displays the dashboard Configuration Settings Accesses the Configuration Settings page where you can view various options or select to receive configuration settings ...

Page 6: ...es the appliance s online help Manual Displays the appliance s configuration manual Logout Logs out of the appliance s dashboard Note A Nyquist appliance connected to the Nyquist network receives a configuration file from the Nyquist server that includes the latest firmware available from the server If the firmware is different from the one installed on the appliance an automatic firm ware update ...

Page 7: ... 5 If you want to return your appliance to its original factory configuration select Restore Factory Settings 6 Select Reboot Appliance to restart your appliance Table 3 Firmware Update settings Current Nyquist Version Shows the version of the appliance s currently installed firmware New Nyquist Version Shows the version of the firmware that has been loaded though not installed onto the appliance ...

Page 8: ...k settings 1 On the appliance web UI s main page select Network Settings 2 Select your desired network settings 3 Select Save Restore Factory Settings Returns the appliance to its original factory con figuration Note This does not install the original appliance firmware The firmware will not be changed Reboot Appliance Restarts the appliance Table 3 Firmware Update settings ...

Page 9: ...o the appliance Netmask Identifies the subnetwork subdivision of an IP net work Gateway Identifies the address or route for the default gate way VLAN ID Identifies the Virtual Local Area Network VLAN for this appliance Values range from 0 to 4094 VLAN Priority Identifies the priority of the network traffic on the VLAN Priority can range from 0 through 7 ...

Page 10: ... on the Nyquist server on port 69 the standard TFTP port and the optional Nyquist DHCP service automatically provides this TFTP address via option 66 Note If this value is unspecified the TFTP Server from DHCP will automatically be set to Yes this field will become read only and DHCP will be used to configure this setting To change this value the TFTP Server from DHCP setting must be set to No whi...

Page 11: ...iguration Settings 2 View the settings as described in Table 5 on page 10 for normal configuration or modify the settings as described in Standalone Operation Configuration Settings on page 11 for Standalone Operation configuration 3 If changes were made Standalone Operation only click the Save Configuration Settings and or Save Multicast Addresses buttons to save your changes DHCP Enabled Indicat...

Page 12: ...st used for emergency all call pages All Call Identifies the IP address port number cut level vol ume and station list used for all call pages Audio Distribution Identifies the IP address port number cut level vol ume and station list used for audio distribution Multicast Identifies the IP address port number cut level vol ume and station list used for the multicast audio stream of one or more zon...

Page 13: ...nabled for this device Figure 6 Appliance Configuration Settings Standalone enabled Table 6 Configuration Settings Standalone enabled Device Type Displays the type of this device Device Name Provides a name for this device Web Username Specifies a web username for this appliance Web Password Specifies a web password for logging into the appliance ...

Page 14: ...ist of codecs allowed on SIP sessions SIP Extensiona Specifies the SIP extension for this device The extension along with the IP address is used to specify the URI used to place a SIP call to this extension sip extension local_ip_address SIP Network Porta Specifies the IP port on which to communicate with the SIP Registration Server typically 5060 SIP User Namea Specifies the SIP user name used to...

Page 15: ...ity audio at 64 kbps The u law version is primarily used in North America and Japan G711 a law Intercom call quality A narrowband audio codec that provides toll qual ity audio at 64 kbps The a law version is primarily used in most countries outside of North America and Japan G722 Tone and paging quality A wideband audio codec operating at 48 56 and 64 kbps OPUS Music quality An audio codec format ...

Page 16: ...dB Note To modify click on the value adjust the slider on the popup using the cursor keys or mouse and click the check box button Note A maximum of 24 multicast entries is supported Multicast Addresses should be ordered by priority highest priority first If multiple streams are active on the same channel simultaneously the one with the highest prior ity will be played Set the Sorting switch to Ena...

Page 17: ...io signals that have been converted to a digital format You can also select Save Settings to Server to back up all configuration settings to the Nyquist server The DSP page allows you to adjust the signal level for the Output channel as well as view ing level indicators for both the input and output signals Selecting the DSP Features button hamburger menu above the OUT signal indicator displays a ...

Page 18: ...adjust the input level until you have a strong signal i e within the green and yellow areas on the meter then adjust the final output levels using the DSP Outputs controls To adjust the channel volume level 1 On the appliance Web UI s main page select DSP 2 Use the channel s slider to adjust the volume level Knob Adjustments Many DSP controls use knobs to adjust one or more settings The value of a...

Page 19: ...com Tuning from the Menu icon on the DSP page displays the Intercom Tuning page The Intercom Tuning page has level indicators for input and output signals and contains the following settings see Table 8 Figure 8 Intercom Tuning Settings ...

Page 20: ... the Menu icon on the DSP page displays the Presets page Table 8 Intercom Tuning Settings Switching Sensitivity Specifies the minimum level of the received signal at which the microphone signal will be muted and the output i e speaker channel will be enabled The range is 90 to 20 dB Talkback Threshold Specifies the minimum talkback i e microphone signal at which talkback will be enabled The lower ...

Page 21: ... the Speaker Type Figure 9 Presets Settings Table 9 Preset Settings Speaker Type Select a predefined Preset configuration from the list of speaker models Available options are NQ S1810CT ceiling mounted speaker NQ S1810WT wall mounted speaker ...

Page 22: ...PC Mac or Android device where they can be copied to removable media or attached to an email for technical support To view a log file 1 On the appliance Web UI s main page select Logs 2 From the drop down menu select the log that you want to view Multiple versions of the same log and zipped copies of the log may be available 3 To export the file select Export A link to a txt file appears in the br...

Page 23: ...the system debug Contains errors and debug information dpkg log Contains information that is logged when a package is installed or removed using dpkg command faillog Contains user failed login attempts kern log Contains information logged by the kernel and recent login information for all users lastlog Contains information on the last login of each user messages Contains messages generated by Nyqu...

Reviews: