BOGE Operating instructions for C 10 L...C 20 L series screw compressors
Page 37
Maintenance
5.3
Regular maintenance work
5.3 Regular maintenance work
Clean or change suction
filter
Cleaning:
–
1 x monthly, however, at least every 500 operating hours.
–
Correspondingly earlier if the air taken in is heavily soiled.
Change:
–
In the event of damage.
–
After the second cleaning.
–
Switch off the compressor with the OFF button.
Fig. 5.2: Changing the suction filter
Cleaning the filter
cartridge
Caution: Risk of injury!
Press Emergency Stop button, open mains disconnection device and secure
against unintentional switch on by means of a padlock.
Removing the filter car-
tridge
Remove lid (1) of the filter
housing.
Remove filter cartridge (2).
Attention!
Do not clean filter cartridges in liquids.
Do not use any hard objects when cleaning to avoid damaging the filter pa-
per.
Refit a new filter cartridge in the event of damage or once it has been cleaned
twice.