BOGE Operating instructions for C 10 L...C 20 L series screw compressors
Page 9
Product description
2.1
Technical data
Part 2: Product description
2.1 Technical data
Technical data for C 10 L...C 20 L compressor assembly, part 1
Type
C 10 L
C 15 L
C 20 L
Dimensions
– Width
[inch]
46.1
52.5
52.5
– Depth
[inch]
23.6
24.2
24.2
– Height
[inch]
23.4
25.3
25.3
Weight
– silenced
[lbs.]
313.2
361.4
361.4
Max. sound pressure level
[± 3 dB(A)]
accord. to DIN 45635, part 13
– silenced / super silenced
[dB(A)]
68
75
75
Reference surface measure
– silenced / super silenced
[dB(A)]
13
13
13
Sound power level
– silenced / super silenced
[dB(A)]
81
88
88
Compressor
max. final compression temperature
[°F]
230
230
230
Volume flow according to
ISO 1217 appendix C at:
– p
max
= 115 psig
[cfm]
–
69
–
– p
max
= 150 psig
[cfm]
36
–
77
Drive motor
Rated power
[Hp]
10
15
20
Nominal speed
– 60 Hz
[min
-1
]
1800
3600
3600
Protection type
TEFC
TEFC
TEFC
ISO class
F
F
F
Electrical connection
Mains voltage
1)
[V]
[Hz]
Recommended fuse protection
2) 3)
[A]
1)
Standard equipment. Mains voltages and frequencies are specified on a plate in the switch cabinet.
2)
The fuse values change in the case of other mains voltages and frequencies.
3)
Use fuse Class RK 5 only.
200
60
40
200
60
70
200
60
70
[V]
[Hz]
Recommended fuse protection
2) 3)
[A]
208 – 230
60
40
208 – 230
60
60
208 – 230
60
60
[V]
[Hz]
Recommended fuse protection
2) 3)
[A]
460
60
25
460
60
30
460
60
30
[V]
[Hz]
Recommended fuse protection
2) 3)
[A]
575
60
15
575
60
30
575
60
30