It is the user’s responsibility to carry out the appropriate 
decontamination if hazardous material is spilled on or inside the 
equipment. 

 

It is the user’s responsibility not to use decontamination or cleaning 
agents that could cause a hazard due to reaction with the equipment 
or material contained in it.   

 

Consult the manufacturer or distribution agent if there is any doubt 
about the compatibility of decontamination or cleaning agents with 
the equipment or material cantained in it. 

 

The Boekel UV Crosslinker is equipped with a UV-protective viewing 
window. This window protects users from harmful UV rays that are 
generated inside of the unit. Do not operate the unit with the door 
open or attempt to defeat the safeguards on the unit. 

 

Do not alter the construction or design. Do not remove safety labels or 
devices. 

 

Do not use this equipment for anything other than its intended 
purpose, as described in this equipment manual. 

 

Used or broken bulbs should be disposed of in accordance with all 
applicable disposal laws. 

 

Do not position the equipment in a manner that makes it difficult to 
disconnect the power cord from the receptacle on the back of the 
unit. 

 

Protection provided by the equipment may be impaired if the 
equipment is used in a manner not specified by the manufacturer. 

 

Do not replace the detachable power cord with an inadequately-
rated cord. 

 
2.0

 

Product Information 

 

The Boekel UV Crosslinker is designed to provide crosslinking of  

 

samples in a safe, time-efficient manner with a controlled  

 

 

amount of ultraviolet radiation.   This unit may be used for: 

 

Crosslinking DNA or RNA to nylon, nitrocellulose or nylon-reinforced 
nitrocellulose membranes 

 

UV sterilization and sanitization 

 

Northern, Southern, dot or slot blot analysis 

 

Nicking of DNA in agarose gels prior to blotting 

 

UV curing 

 

The  Boekel  UV  Crosslinker  is  uniquely  designed  with  a  variable  height 
adjustment which may be lowered or raised based on the size of  the 
sample.    Building  up  the  height  of  samples  to  get  them  closer  to  the 
bulbs  is  no  longer  necessary.    The  microprocessor  controls  detect  the 
exact  energy  of  the  bulbs  and  compensate  accordingly  by  giving 
more accurate energy readings than competing products that do not 

Summary of Contents for 234100

Page 1: ...N2400340 Rev 2 Page 1 BOEKEL UV CROSSLINKER Model 234100 115VAC 175W 1 6A 234100 2 230VAC 175W 0 8A OPERATING INSTRUCTIONS...

Page 2: ...Identification of Controls 5 5 0 Installation 7 6 0 Operation 7 7 0 Technical Specifications 9 8 0 Maintenance and Service 9 8 1 Calibration 9 8 2 Changing Bulbs 10 8 3 Cleaning 11 8 4 Contrast Adjust...

Page 3: ...traviolets Prot ger les yeux et la peau des rayons ultraviolets nocifs Always observe the following safety precautions Avoid exposure to direct or strongly reflected germicidal ultraviolet rays Germic...

Page 4: ...h all applicable disposal laws Do not position the equipment in a manner that makes it difficult to disconnect the power cord from the receptacle on the back of the unit Protection provided by the equ...

Page 5: ...he unit when changing bulbs 3 0 Assembly Remove the packing materials carefully and retain for future shipment or storage of the unit Inspect for damage Report all shipping damage to the carrier immed...

Page 6: ...N2400340 Rev 2 Page 6 Figure 1 Front View Figure 2 Back View 1 LCD DISPLAY 2 POWER KEY 3 MODE KEY 4 RESET KEY 5 START STOP KEY 6 UP DOWN ARROW KEYS 7 AC POWER SOCKET 8 HEIGHT ADJUSTMENT KNOB...

Page 7: ...gy Mode is selected The Up and Down keys are used with a speedup algorithm to set the desired target energy value If the Mode key is pressed the colon for time blinks showing that Time Mode is selecte...

Page 8: ...ws the following for 1 second The user is returned to the main screen in paused mode where they can adjust the target energy or time CYCLE PAUSED blinks every 2 seconds to remind the user that the cyc...

Page 9: ...he requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements 8 0 Maintenance and Servic...

Page 10: ...cement of pins in sockets at both ends of each bulb that is installed 8 2 2 To use a different wavelength the entire set of 5 bulbs must be replaced with a set of 5 bulbs of the desired wavelength See...

Page 11: ...agents other than mild soap and water on the viewing window as damage to the window may result 8 4 Contrast Adjustment 8 4 1 To increase or decrease the contrast level of the display power the unit on...

Page 12: ...t bulbs are operational and replace blown bulbs as needed Duration of Energy Mode significantly longer than usual for given amount of energy a Blown bulb s a Ensure all light bulbs are operational and...

Page 13: ...rtificate must be completed signed by the user and returned to Boekel Scientific in order to receive the RMA number Please be sure to mark the outside of the returned goods package with the RMA number...