Boekel 234100 Operating Instructions Manual Download Page 13

N2400340   Rev. 2 

Page 13 

 

 
11.0  Service 
 

It  is  required  to  obtain  a  Return  Material  Authorization  (RMA)  number 

 

prior  to  the  return  of  any  Boekel  product,  for  any  reason.    A 

 

Decontamination  Certificate  must  be  completed,  signed  by  the  user 

 

and returned to Boekel Scientific in order to receive the RMA number.   

 
 

Please  be  sure  to  mark  the  outside  of  the  returned  goods  package 

 

with the RMA number, in order to ensure prompt handling. 

 
 

 

 

 

Boekel Scientific 

 

 

 

 

855 Pennsylvania Blvd. 

 

 

 

 

Feasterville, PA  19053 

 

 

 

 

Phone:  215-396-8200 or 800-336-6929 

 

 

 

 

Fax:  215-396-8264 

 

 

 

 

Email:  [email protected] 

 
 
 
 
 
 
 
 

 

Summary of Contents for 234100

Page 1: ...N2400340 Rev 2 Page 1 BOEKEL UV CROSSLINKER Model 234100 115VAC 175W 1 6A 234100 2 230VAC 175W 0 8A OPERATING INSTRUCTIONS...

Page 2: ...Identification of Controls 5 5 0 Installation 7 6 0 Operation 7 7 0 Technical Specifications 9 8 0 Maintenance and Service 9 8 1 Calibration 9 8 2 Changing Bulbs 10 8 3 Cleaning 11 8 4 Contrast Adjust...

Page 3: ...traviolets Prot ger les yeux et la peau des rayons ultraviolets nocifs Always observe the following safety precautions Avoid exposure to direct or strongly reflected germicidal ultraviolet rays Germic...

Page 4: ...h all applicable disposal laws Do not position the equipment in a manner that makes it difficult to disconnect the power cord from the receptacle on the back of the unit Protection provided by the equ...

Page 5: ...he unit when changing bulbs 3 0 Assembly Remove the packing materials carefully and retain for future shipment or storage of the unit Inspect for damage Report all shipping damage to the carrier immed...

Page 6: ...N2400340 Rev 2 Page 6 Figure 1 Front View Figure 2 Back View 1 LCD DISPLAY 2 POWER KEY 3 MODE KEY 4 RESET KEY 5 START STOP KEY 6 UP DOWN ARROW KEYS 7 AC POWER SOCKET 8 HEIGHT ADJUSTMENT KNOB...

Page 7: ...gy Mode is selected The Up and Down keys are used with a speedup algorithm to set the desired target energy value If the Mode key is pressed the colon for time blinks showing that Time Mode is selecte...

Page 8: ...ws the following for 1 second The user is returned to the main screen in paused mode where they can adjust the target energy or time CYCLE PAUSED blinks every 2 seconds to remind the user that the cyc...

Page 9: ...he requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating the same level of testing requirements 8 0 Maintenance and Servic...

Page 10: ...cement of pins in sockets at both ends of each bulb that is installed 8 2 2 To use a different wavelength the entire set of 5 bulbs must be replaced with a set of 5 bulbs of the desired wavelength See...

Page 11: ...agents other than mild soap and water on the viewing window as damage to the window may result 8 4 Contrast Adjustment 8 4 1 To increase or decrease the contrast level of the display power the unit on...

Page 12: ...t bulbs are operational and replace blown bulbs as needed Duration of Energy Mode significantly longer than usual for given amount of energy a Blown bulb s a Ensure all light bulbs are operational and...

Page 13: ...rtificate must be completed signed by the user and returned to Boekel Scientific in order to receive the RMA number Please be sure to mark the outside of the returned goods package with the RMA number...

Reviews: