29
Remark: After replacing lower controller and replacing the parts for E5/E6 issue, please follow steps below to
re-calibrate the machine
1.1 Press PROG and SPE+ KEY at the same time and POWER UP or reset SAFETY KEY entry. After entry, LCD will
run display testing, all segment will lights up to show according.
1.2 If press START KEY, the computer will take the default data to calibrate and save into EEPROM.
1.3 Press MODE to entry unit setting mode
1.4 Press MODE to entry the setting mode of WHEEL SIZE
1.5 Press MODE to entry the setting mode of MIN SPEED
1.6 Press MODE to entry the setting mode of MAX SPEED
1.7 Press MODE to entry the setting mode of MAX ELEVATION
1.8 Press START KEY to entry SPEED CALIBRATE, It will show “CAL” in the window of SPEED in sprinkle. After
calibrate will back to IDLE MODE automatically.
You can start to use your treadmill after the calibration test be done
Current overload Protection ,
the motor electrical is overload
Stop and go into fault status, computer buzzle will ring 3 tones
and shows fault code“E3”. Other areas show blank. After 10
seconds will go into ready mode, and can restart.
Possible Reasons
:
Over the rated load cause too much electricity
that make system Self-preservation or some parts blocked and
make DC motor can’t process. Adjust the machine and restart.
Another please check the DC motor or controller have any burned
smell or not. If yes, please change the motor or controller. Another
make sure the power and voltage is comply with standard.
E4
Incline self-learning fault
Check incline motor sense wire and AC wire are inserted well; AC
wire is right inserted according to the indentify in the incline
motor; make sure the incline motor wire without damager; after
check those, press the button on controller, then start self-learning
again.
E5
Incline sensor error
Check incline motor sense wire and AC wire are inserted well; AC
wire is right inserted according to the indentify in the incline
motor; make sure the incline motor wire without damager; after
check those, press the button on controller, then start self-learning
again.
E6
Explosion-Proof Protection
:
Some unusual condition of
power or voltage that cause
damage to the motor drive
circuit.
Stop and go into fault status, computer buzzle will ring 3 tones
and shows fault code“E6”. Other areas show blank. If recover then
go into ready mode, then can restart.
Possible Reasons
:
The power voltage is less than normal or the
controller has some problems. Make sure the motor wire is
connecting well.
E7
The upper EEPROM is
recorded faulty
Change upper EEPROM
E8
The lower EEPROM is
recorded faulty
Change lower EEPROM
Summary of Contents for JSPORT3000