background image

 

 

INSTALLATION REQUIREMENTS 

 

READ THIS ENTIRE INSTALLATION AND SERVICE GUIDE BEFORE BEGINNING INSTALLATION 

The Body Glove Reverse Osmosis (RO) Drinking Water System has been designed for ease of installation and 
serviceability and is constructed with the finest materials available.  Using these instructions and paying close attention to 
the parameters outlined within "CONDITIONS FOR USE" detailed on Page II will ensure a successful installation. 
 

The Body Glove System must be installed in accordance with applicable city, state, provincial and local plumbing 
codes

.  To ensure the system continues to operate at its optimum level, it is necessary to use a routine maintenance and 

replacement schedule (See table 4 below). The frequency at which filters must be changed will depend on the quality of 
feed water supply and the level of system usage. 
 
The Body Glove RO system contains replaceable filter components critical to the efficiency of the system.   
Replacement of the reverse osmosis filter components should be with one of identical specification, as defined by Water, 
Inc. to assure the same efficiency.  Product water shall be tested periodically to verify the system is performing properly.   
The Body Glove RO operator may perform the periodical water test using the Smartap

®

 Water Quality Monitor. 

 

All state, provincial and local government codes regarding installation of these devices must be observed. 

 

PREPARATION 

1.  Check that all appropriate components are packed 

with your system (Figures 1.A. and 1.B., pgs. III & IV). 
  

 

 

2.  Determine location for RO component installation.  

Two requirements for consideration are: access to 
cold water supply line and household sink drainpipe. 
Specific requirements are detailed in Table 3. 

 

COMPONENT LOCATION REQUIREMENTS 

Table 3 

PRODUCT WATER FAUCET 

Faucet may be installed in any convenient location. 

Make sure underside of location is free of obstructions. 

REVERSE OSMOSIS MODULE 

Module may be installed under sink or in any convenient 

location within 15 feet of source water supply and faucet. 

STORAGE TANK 

Tank may be placed in any space within 15 feet of faucet, generally under kitchen sink or in an adjacent unused cabinet. 

Tubing length between components should be kept to a minimum, avoiding sharp bends or kinks. 

DO NOT PLACE MODULE WHERE IT WILL BE EXPOSED TO FREEZING AND/OR DIRECT SUNLIGHT. 

MODULE MUST BE EASILY REMOVABLE FOR PERFORMANCE OF ROUTINE MAINTENANCE.

 

Mount Module on side of cabinet using bracket (attached to Module) and two screws provided in the Installation Kit. 

HOLD THE MODULE BY THE FILTER HOUSINGS WHEN PICKING UP OR CARRYING UNIT.

 

 

NOTE 

THIS BODY GLOVE DRINKING WATER SYSTEM IS FOR USE ON POTABLE WATER SUPPLIES ONLY.  

SOURCE WATER EXCEEDING CHEMICAL PARAMETERS REQUIRES PRE-TREATMENT. 

 

CAUTION

 

DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY 

WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.

 

 

BODY GLOVE RO MAINTENANCE REQUIREMENTS 

Table 4 

Service Requirements 

Recommended Service Intervals 

To insure the system operates at its optimum level, certain routine 

maintenance must be performed.  Frequency of maintenance performance 

will depend on feed water quality and level of system usage. 

CLEAN:

   Each time filters are replaced 

SANITIZE:

  At least once a year and each time membrane is replaced. 

Replace filters as required or every 6 to 12 months 

depending on feed water quality. 

Replace membrane as required based on Smartap

®

  

Water Quality Monitor indication or periodic TDS rejection tests. 

Maximum recommended service life for membrane is 60 months. 

Summary of Contents for BG-Pure

Page 1: ...BG Pure OWNER S GUIDE ADVANCED REVERSE OSMOSIS WATER FILTER SYSTEM This model is tested and certified by WQA against NSF ANSI 58 for the reduction of TDS 4VTFC25G PB Model WI BG PURE ...

Page 2: ...owing information and retain for reference Model Number WI BG PURE Serial Number _____________________________________ Date Purchased ____________________________________ Date Installed ______________________________________ ...

Page 3: ...r keep a container of RO water in the fridge to enjoy the clean fresh taste of purified water Alternatively take it directly from the faucet dispenser o Ice Cubes use RO water to fill ice cube trays Ice cubes made from RO water are typically clearer and better tasting than ice made from non filtered tap water o Automatic Ice Makers a water line from the RO system can be plumbed to refrigerators wi...

Page 4: ... Cl2 2 0 Turbidity 1 0 NTU Nephelometric Turbidity Unit Silt Density Index Value stated in SDI units Maximum SDI 4 0 NOTES 1 TFC refers to reverse osmosis membranes constructed from a THIN FILM COMPOSITE 2 The daily production rate is the volume of product water produced by the system per day and is determined by testing in accordance with the procedure outlined in NSF ANSI Standard 58 3 System s ...

Page 5: ...40600040 n s not shown PRODUCT WATER FAUCETS Item Description Part No 7 8 Chrome Plated Metal Air Gap Connector Faucet 3 8 x 7 16 92192 Fig 7 92407 INSTALLATION KIT 9 10 11 12 13 14 n s n s n s Complete Kit Supply Valve Saddle Tapping Drain Clamp Saddle Clamp Air Gap 3 8 Tubing 3 8 Red Tubing 3 8 Blue Tubing 3 8 White Tubing 1 4 White Screw Mounting Bracket 2 each Elbow Stem 3 8 2 each Elbow Stem ...

Page 6: ...GENERAL INFORMATION PRODUCT WATER STORAGE TANK PRODUCT WATER STORAGE TANK Item Description Part No 1 2 Storage Tank Assembly Metal Ball Valve 3 8 92342 92294 33503601 Figure 1 B Product Water Storage Tank ...

Page 7: ...e Specific requirements are detailed in Table 3 COMPONENT LOCATION REQUIREMENTS Table 3 PRODUCT WATER FAUCET Faucet may be installed in any convenient location Make sure underside of location is free of obstructions REVERSE OSMOSIS MODULE Module may be installed under sink or in any convenient location within 15 feet of source water supply and faucet STORAGE TANK Tank may be placed in any space wi...

Page 8: ...ssed at any time the most accurate readings are obtained when the system is making water for at least 10 minutes INTER COMPONENT CONNECTIONS Connections between cold water supply line Body Glove RO Module storage tank product water faucet and drain line are accomplished using plastic tubing and push together quick connect type fittings PLASTIC TUBING 1 Cut tube ends square and straight Do not defo...

Page 9: ...ng compression fitting a Slide nut and sleeve onto tubing in that order b Install insert into plastic tubing c Install tube with insert and sleeve into valve body d Thread compression nut onto valve body tighten 5 Turn saddle tapping valve handle clockwise until it is firmly seated and piercing lance is fully extended 6 CAUTION Supply line is pierced and valve is closed Do not open valve until sys...

Page 10: ... P S trap between trap and sink Figure 4 Drain Hole Location and Installation Air Gap Faucet NOTE See Page III Figure 1 A for connection to drain for Non Air Gap Faucet 1 Select a location for drain hole based on type of sink and orientation of drain line Figure 4 2 Position drain outlet saddle Figure 5 Item 1 on drainpipe Allow adequate space for drilling operation 3 Tighten saddle bolts evenly o...

Page 11: ...ure pilot guide is inserted tightly Insert pilot guide into pilot hole Push down gently on drill motor to apply light pressure to porcelain surface Start drill motor turning as slowly as possible After initial cut has started motor speed may be gradually increased The cut may require three to four minutes to complete Going faster could result in excessive chipping Be sure a complete ring has been ...

Page 12: ...ng washer faucet washer and nut Items 4A 6 and 7 onto faucet nipple below sink and snug them up Be sure to align faucet properly before tightening Do not over tighten 6 Install faucet connector Item 8 packaged with faucet onto faucet nipple Install 3 8 blue tube into faucet connector 7 Trim 3 8 blue tube to desired length Install 3 8 blue tube into 3 8 blue collet located on side of module near sy...

Page 13: ...01 or 92192 1 2 3 4 4A 5 6 7 8 Body Faucet Faucet Base Washer Rubber Faucet Base Washer Metal Washer Slotted Air Gap Slot Shape may vary Washer Locating Non Air Gap Replaces Items 4 and 5 not shown Spacer Faucet Air Gap Washer Faucet Nut Faucet Connector Faucet 3 8 x 7 16 Figure 7 Chrome Plated Metal Product Water Faucet Assembly ...

Page 14: ...fold Assembled Cartridge Sediment 5 micron Filter Membrane Thin Film Composite 25 GPD Yellow Casing Black Tape Cartridge Carbon AES 10 micron O Ring Filter Housing Housing Filter Circuit Board Battery 9 volt Elbow Stem 3 8 Elbow Stem 1 4 Kit O Rings Collets QC 3 8 Safety Clips Safety Clips 3 8 Note These parts are included with installation kit Includes Items 2 3 4 5 n s not shown 20500127 3270103...

Page 15: ...connections for leaks and correct if necessary Icemaker Extra point of use Check connections on these supply lines for leaks 10 Allow storage tank to fill overnight 11 WARNING DO NOT USE THE FIRST FULL STORAGE TANK OF WATER Discard to drain first full tank of water by opening product water and extra point of use faucet until water flow stops then close faucet This will flush sanitizing solution fr...

Page 16: ...water Inspect them for damage i e nicks scratches Replace damaged O rings 8 CAUTION Do not allow the Smartap Water Quality Monitor electronics wiring or connectors to get wet Clean filter housings and manifold ports inside and outside with washcloth and cleaning solution Do not use abrasive materials 9 Rinse manifold housings with clean potable water 10 Inspect manifold and filter housing O ring g...

Page 17: ...Remove battery by sliding it out of its holder 26 Slide new battery into its holder 27 CAUTION Verify battery connector alignment before making connection Figure 9 Connect battery by pressing clip onto battery terminals NOTE Release button immediately after light illuminates Test is to confirm battery connection not water quality 28 Test battery connection by activating monitor Press push button I...

Page 18: ...actory drain storage tank sanitize system and replace membrane Drain storage tank and let it refill overnight LEAKAGE AND NOISE Symptom Probable Cause Solution Leak at fitting Tubing not pushed completely into fitting Defective tube Push tube into fitting past O ring seal Cut damaged area from tube or replace tube See Page 2 Figure 2 Leak at filter housings O ring has not seated properly O ring ha...

Page 19: ...er system is altered by anyone other than Water Inc the warranty shall be void ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THE PERIOD SPECIFIED ABOVE FOR THE PARTS DESCRIBED IN THIS LIMITED WARRANTY Water Inc does not know the characteristics of your water supply The quality of water supplies ma...