1
INSTALLATION REQUIREMENTS
READ THIS ENTIRE INSTALLATION AND SERVICE GUIDE BEFORE BEGINNING INSTALLATION
The Body Glove Reverse Osmosis (RO) Drinking Water System has been designed for ease of installation and
serviceability and is constructed with the finest materials available. Using these instructions and paying close attention to
the parameters outlined within "CONDITIONS FOR USE" detailed on Page II will ensure a successful installation.
The Body Glove System must be installed in accordance with applicable city, state, provincial and local plumbing
codes
. To ensure the system continues to operate at its optimum level, it is necessary to use a routine maintenance and
replacement schedule (See table 4 below). The frequency at which filters must be changed will depend on the quality of
feed water supply and the level of system usage.
The Body Glove RO system contains replaceable filter components critical to the efficiency of the system.
Replacement of the reverse osmosis filter components should be with one of identical specification, as defined by Water,
Inc. to assure the same efficiency. Product water shall be tested periodically to verify the system is performing properly.
The Body Glove RO operator may perform the periodical water test using the Smartap
®
Water Quality Monitor.
All state, provincial and local government codes regarding installation of these devices must be observed.
PREPARATION
1. Check that all appropriate components are packed
with your system (Figures 1.A. and 1.B., pgs. III & IV).
2. Determine location for RO component installation.
Two requirements for consideration are: access to
cold water supply line and household sink drainpipe.
Specific requirements are detailed in Table 3.
COMPONENT LOCATION REQUIREMENTS
Table 3
PRODUCT WATER FAUCET
Faucet may be installed in any convenient location.
Make sure underside of location is free of obstructions.
REVERSE OSMOSIS MODULE
Module may be installed under sink or in any convenient
location within 15 feet of source water supply and faucet.
STORAGE TANK
Tank may be placed in any space within 15 feet of faucet, generally under kitchen sink or in an adjacent unused cabinet.
Tubing length between components should be kept to a minimum, avoiding sharp bends or kinks.
DO NOT PLACE MODULE WHERE IT WILL BE EXPOSED TO FREEZING AND/OR DIRECT SUNLIGHT.
MODULE MUST BE EASILY REMOVABLE FOR PERFORMANCE OF ROUTINE MAINTENANCE.
Mount Module on side of cabinet using bracket (attached to Module) and two screws provided in the Installation Kit.
HOLD THE MODULE BY THE FILTER HOUSINGS WHEN PICKING UP OR CARRYING UNIT.
NOTE
THIS BODY GLOVE DRINKING WATER SYSTEM IS FOR USE ON POTABLE WATER SUPPLIES ONLY.
SOURCE WATER EXCEEDING CHEMICAL PARAMETERS REQUIRES PRE-TREATMENT.
CAUTION
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY
WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
BODY GLOVE RO MAINTENANCE REQUIREMENTS
Table 4
Service Requirements
Recommended Service Intervals
To insure the system operates at its optimum level, certain routine
maintenance must be performed. Frequency of maintenance performance
will depend on feed water quality and level of system usage.
CLEAN:
Each time filters are replaced
SANITIZE:
At least once a year and each time membrane is replaced.
Replace filters as required or every 6 to 12 months
depending on feed water quality.
Replace membrane as required based on Smartap
®
Water Quality Monitor indication or periodic TDS rejection tests.
Maximum recommended service life for membrane is 60 months.