28
Cosmos - Helios - Solaris
- Check that the appliance installed is right for the type of gas used (the appliance can be installed
for natural gas or propane).
- Your supplier is the SPECIALIST chosen by BODART&GONAY to represent your region. For your
SAFETY and SATISFACTION, we recommend that you have them carry out your installation.
- Before installation, check that local supply conditions (identification of gas and pressure category)
and the appliance settings are compatible.
- If LPG is used, check that the pressure reducing valve gives the right pressure, i.e. 37mbar.
- This appliance must be installed in accordance with the regulations in force. We recommend that
you comply with the various local installation regulations for air-vent appliances.
- The gas air-vent fireplace must be connected by an approved installer in accordance with the
standard NBN D51/003 or NBN D51/006 LPG for Belgium and standard NFD 35-377 or Document
Technique Unifié (DTU P45 204) for France.
- If your chimney has previously been used with another heating or kitchen appliance, you
must have it swept before positioning the chimney flue. The chimney flue and its connection
to the fireplace must be airtight and clean. The chimney must be made with the:
For the COSMOS 145
“ONTOP” US 130-200 flue system
“POUJOULAT” 130-200 EI flue
For the COSMOS 100, HELIOS and SOLARIS
“ONTOP” US 100-150 flue system
“POUJOULAT” 100-150 EI flue
Only installations mentioned in the paragraph “chimney installation” are permitted.
- Only install the draught limiter if there is a difference in vertical length of over 3m in relation to
the horizontal length.
- Logs (optional) must be laid flat on the “coal” bed (gravel).
- Your appliance has been correctly adjusted and sealed in the factory. If, because of local
circumstances, adjustments need to be made, they can only be done by the approved installer.
Any intervention by the user will lead ipso facto to annulment of the guarantee.
- Any installer wishing to change an appliance from one gas category to another MUST contact the
manufacturer.
1
IMPORTANT RECOMMENDATIONS