WARNING
Before installing please ensure that all the power is turned off. Connect
the work return lead to the machine. Ensure that the work return
lead is firmly connected before connecting the power plug in to the
electrical output socket. Ensure free flow of air around machine to avoid
overheating.
5.1 Installation for TIG setup
1
Connect one end of the work return lead to positive of the front
panel, and fasten it clockwise. Connect the other end of the clamp to
the work piece.
2
Connect the gas cylinder to the regulator. Select correct shielding gas
for the application.
3
Connect the dinse plug of the TIG torch to negative of the front
panel, and fasten it clockwise.
4
Connect securely the gas lead of the TIG torch to the gas output
terminal
.
5
Connect the 5-pin plug of the TIG torch to the Torch/foot contol socket
and fasten the screw.
5.2 Installation for TIG setup with
optional foot control
1
Connect one end of the work return lead to positive of the front
panel, and fasten it clockwise. Connect the other end of the clamp to
the work piece.
2
Connect the gas cylinder to the regulator. Select correct shielding gas
for the application.
3
Connect the dinse plug of the TIG torch to negative of the front
panel, and fasten it clockwise.
4
Connect securely the gas lead of the TIG torch to the gas output
terminal
.
5
Connect the electical lead of the foot control to the 5-pin Torch/foot
contol socket
and fasten the screw.
6
The 5-pin plug of the TIG torch should now hang free.
5.0 Smootharc TIG 185 AC/DC installation
GAS
VRD
GAS
VRD
MAX
MIN
Installation for TIG setup
Installation for TIG setup using foot control
22
BOC Smootharc TIG 185 AC/DC Operating Manual
Summary of Contents for Smootharc TIG185 AC/DC
Page 1: ...Smootharc TIG185 AC DC Operating Manual...