![BOC E2M28 Instruction Manual Download Page 33](http://html1.mh-extra.com/html/boc/e2m28/e2m28_instruction-manual_2781946033.webp)
E2M28 and E2M30 Rotary Vacuum Pumps
OP
ERATION
PAGE
27
Issue K
27
Jul 05
4.8
Shut-down
Note: If the gas-ballast control is open and the motor is switched off for any reason, the pump drive shaft may
rotate in the reverse direction, causing a system pressure rise. To prevent this, use a gas-ballast control
valve (refer to Section 7.4.15).
We recommend, as described in the procedure below, that you decontaminate the oil before you shut
down the pump; this will prevent damage to the pump by the contaminates in the oil.
1.
Refer to Section 4.6 and decontaminate the oil, as required.
2.
Close the vacuum system isolation-valve (if not already closed).
3.
Close gas-ballast (that is, turn the gas-ballast control clockwise).
4.
Switch off the electrical supply to the pump.