E2M28 and E2M30 Rotary Vacuum Pumps
TECHNIC
A
L
D
A
TA
PAGE
6
Issue K
6
Jul 05
2.3
Mechanical data
2.4
Lubrication data
Note: A BOC Edwards Material Safety Data Sheet for the oil specified below is available on request.
2.5
Electrical data
Refer to Tables 5 and 6. The motor start-up current is drawn for less than one second, so you must use
slow-blow fuses to prevent unnecessary fuse failure when the pump starts. Fuses should be to EN60269
Section 2.2. For conformance with CSA standards only CSA certified fuses are to be used. If you use the
pump at temperatures lower than 13 ºC, the start-up current will be drawn for longer; this may cause
the motor thermal overload device to open.
Approximate pump mass
44 kg
Dimensions
See Figure 2
Degree of protection
Single-phase motors
Three-phase motors
IP44
IP54
Pump inlet port
NW25 (the flange can be removed from the 1 inch BSP
threaded hole)
Pump outlet port
15 mm external diameter nozzle (the nozzle can be
removed from the
3
/
4
inch BSP threaded hole)
Table 3 – Mechanical data
Recommended oil *
Ultragrade 19
Maximum oil capacity
1.32 litres
* To operate the pump when the ambient temperature is outside the range specified in Section 2.1, or
to optimise pump performance when you process condensible vapours, you may need a different oil.
Table 4 – Lubrication data
Summary of Contents for E2M28
Page 6: ...E2M28 and E2M30 Rotary Vacuum Pumps PAGE iv Issue K iv Jul 05 This page intentionally blank...
Page 16: ...E2M28 and E2M30 Rotary Vacuum Pumps PAGE 10 Issue K 10 Jul 05 This page intentionally blank...
Page 34: ...E2M28 and E2M30 Rotary Vacuum Pumps PAGE 28 Issue K 28 Jul 05 This page intentionally blank...
Page 42: ...E2M28 and E2M30 Rotary Vacuum Pumps PAGE 36 Issue K 36 Jul 05 This page intentionally blank...
Page 44: ...E2M28 and E2M30 Rotary Vacuum Pumps PAGE 38 Issue K 38 Jul 05 This page intentionally blank...
Page 51: ...This page intentionally blank...