Electrical Connection
Check Dryer Operation
Maintenance
Replace Cover
1. Replace cover by positioning the top retaining bracket at top rear
edge of cover, behind the back of mounting base. Tilt cover
downwards and over flange on air inlet/outlet grille. Ensure that the
rubber strip is in place between the cover and the grille.
NOTE:
Space between cover and wall must be the same on both sides.
2. Tighten the single cover-locking screw located in
recess in the air inlet/outlet grille.
1. Turn electrical supply on. Position hands under air-outlet
opening and dryer should turn on. Remove hands from under
air-outlet opening and dryer should stop.
WARNING: MOTOR LAMINATIONS ARE LIVE. TURN ELECTRICAL POWER SUPPLY OFF BEFORE DOING ANY
MAINTENANCE OR SERVICE TO DRYER. DRYER MUST NOT BE OPERATED UNLESS COVER IS IN PLACE.
1. Exterior of cover should be cleaned with a damp cloth to remove dust and surface dirt. Do not use abrasive agents or solvents as
they may permanently damage surface of cover.
2. At least once every 6 months remove cover. Using a small brush or vacuum, clean out buildup of dust and lint from air-intake grille
and
baffle.
NOTE:
if dryer is installed where there is a lot of dust and dirt in the air, the interior of the dryer should be cleaned out more
frequently.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1. Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In the United States and Canada use No.
12 wire or larger.
2. Wiring Instructions:
a. This appliance is intended for connection to fixed wiring.
b.
A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
c.
Check that the electrical rating shown on the Hand Dryer (rating label) is compatible with the electrical supply.
d.
WARNING: THIS PRODUCT MUST BE EARTHED.
e.
Installation and wiring must conform to current IEE Regulations (UK), local or appropriate regulation (other countries).
f.
For 115 Volt Dryers:
Connect ground/earth supply the terminal marked , the
Live supply
to terminal marked
L
and
neutral supply to terminal marked
N
.
A DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
g.
For 208–240 Volt Dryers:
Connect ground/earth supply the terminal marked and the 208-240 Volt wires to terminals
marked
L (L1)
and
N (L2)
.
3. Secure electrical wire in strain relief clamp provided on mounting base.