Figure 1
Form
No.
38030-69 Revised
6/30/16 ©
2016
by
Bobrick
Washroom
Equipment,
Inc. Printed
in
U.S.A.
INSTALLATION OF CABINET:
Provide framed rough wall opening 362mm (14-1/4") wide x 1412mm (55-9/16") high. Minimum recessed depth
required to finish face of wall is 100mm (4"). Allow clearance for construction features that may protrude into rough
wall opening from opposite wall. Coordinate with mechanical engineer to avoid pipes, vents and conduits. If unit
projects above top of wainscot, provide channel or other filler to eliminate gap between cabinet flange and finish face
of wall. Mount unit in wall opening with shims between framing and cabinet at all points indicated by an “S” in Figure
1, then secure unit with 4.2 x 32mm (#8 x 1-1/4") sheet-metal screws (not furnished). Provide electrical service from
nearest distribution panel to dryer mounting base in conformance with local electrical codes.
ELECTRICAL CONNECTION OF HAND DRYER:
Electrical supply entry holes are located in the rear of the cabinet at lower right
corner of the dryer mounting base and at the right side of the cabinet. Supply
cable with supplementary insulation into one of these locations in the unit
cabinet. Cabinet should be fitted with a conduit connection. Plastic grommet
supplied to use as necessary.
1. Connect dryer to nearest distribution panel. Use wire as required by local
electrical code, 3.31mm² dia. (No. 12) wire or larger.
2. Wiring Instructions:
a. This appliance is intended for connection to fixed wiring.
b. A fused means for disconnection in all poles must be provided in the
fixed wiring in accordance with the wiring rules.
c. Check that the electrical rating shown on the dryer (rating label) is
compatible with the electrical supply.
d. WARNING: THIS PRODUCT MUST BE GROUNDED (EARTHED).
e. Installation and wiring must conform to current IEE Regulations (UK),
local or appropriate regulation (other countries).
f. For 208–240 Volt dryers: Connect ground/earth supply the terminal
marked and the 208-240 Volt wires to terminals marked L (L1) and N
(L2).
3. Secure electrical wire in strain relief clamp provided on mounting base.
Figure 2
To remove dryer cover, remove two
screws from the bottom of the Dryer and
two from the sides, as shown in Figure 2.
396mm
15- 5/8"
S
S
S
S
S
S
Recommended Mounting Height Off Floor
for United Kingdom BS8300:2009
1567 to 1674mm 61-11/16" to 65-7/8"
219mm
8-5/8"
89mm
3-1/2"
Typ.
22mm
.88"
Diameter
Hole for
Between-Wall
Wirirng
1450mm
57-1/16"
Dryer
Sensor
Dryer
Outlets
Lock
& Key
Removable
Waste Bin
25mm
1"
Typ.
346mm
13-5/8"
Finish Face of Floor
Paper
Towel
Dispenser
96mm
3-13/16"
280mm
11"
Finish Face of Wall
14mm
9/16"
Typ.
280mm
11"
62mm
2-7/16"
407mm
16"
34mm
1-3/8"
Typ.
16mm
5/8"
22mm
.88"
Diameter
Hole for
Between-Wall
Wirirng
1398mm
55"
100mm
3-15/16"
Recommended Mounting Height Off Floor
for A
ustralian DD
A standar
ds,
AS1428.1-2009
1667 to 1774mm 65-5/8" to 69-13/16"
727mm
28-5/8"