INSTALLATION OF CABINET:
Provide framed rough wall opening 362mm (14-1/4") wide x 1412mm (55-9/16") high. Minimum recessed depth 
required to finish face of wall is 100mm (4"). Allow clearance for construction features that may protrude into rough 
wall opening from opposite wall.  Coordinate with mechanical engineer to avoid pipes, vents and conduits. If unit 
projects above top of wainscot, provide channel or other filler to eliminate gap between cabinet flange and finish face 
of wall. Mount unit in wall opening with shims between framing and cabinet at all points indicated by an “S” in Figure 
1, then secure unit with 4.2 x 32mm (#8 x 1-1/4") sheet-metal screws (not furnished).  Provide electrical service from 
nearest distribution panel to dryer mounting base in conformance with local electrical codes.

ELECTRICAL CONNECTION OF HAND DRYER:
Electrical supply entry holes are located in the rear of the cabinet at lower right 
corner of the dryer mounting base and at the right side of the cabinet. Supply 
cable with supplementary insulation into one of these locations in the unit 
cabinet. Cabinet should be fitted with a conduit connection. Plastic grommet 
supplied to use as necessary.
  1.   Connect dryer to nearest distribution panel. Use wire as required by local  
      electrical code, 3.31mm² dia. (No. 12) wire or larger.
  2.   Wiring Instructions:
      a.   This appliance is intended for connection to fixed wiring.
      b.   A fused means for disconnection in all poles must be provided in the  
          fixed wiring in accordance with the wiring rules.
      c.   Check that the electrical rating shown on the dryer (rating label) is  
          compatible with the electrical supply.
      d.   WARNING: THIS PRODUCT MUST BE GROUNDED (EARTHED).
      e.   Installation and wiring must conform to current IEE Regulations (UK),  
          local or appropriate regulation (other countries).
      f.    For 208–240 Volt dryers: Connect ground/earth supply the terminal  
          marked and the 208-240 Volt wires to terminals marked L (L1) and N  
          (L2).
  3.   Secure electrical wire in strain relief clamp provided on mounting base.

Figure 2

To remove dryer cover, remove two 

screws from the bottom of the Dryer and 

two from the sides, as shown in Figure 2.

396mm

15- 5/8"

S

S

S

S

S

S

Recommended Mounting Height Off Floor

for United Kingdom BS8300:2009 

1567 to 1674mm     61-11/16" to 65-7/8"

219mm

8-5/8"

89mm

3-1/2"

Typ.

22mm

.88"

Diameter

Hole for 

Between-Wall

Wirirng

1450mm

57-1/16"

Dryer

Sensor

Dryer

Outlets

Lock

& Key

Removable

Waste Bin

25mm

1"

Typ.

346mm

13-5/8"

Finish Face of Floor

Paper

Towel

Dispenser

96mm

3-13/16"

280mm

11"

Finish Face of Wall

14mm

9/16"

Typ.

280mm

11"

62mm

2-7/16"

407mm

16"

34mm

1-3/8"

Typ.

16mm

5/8"

22mm

.88"

Diameter

Hole for 

Between-Wall

Wirirng

1398mm

55"

100mm

3-15/16"

Recommended Mounting Height Off Floor

for A

ustralian DD

A standar

ds,

 AS1428.1-2009 

1667 to 1774mm     65-5/8" to 69-13/16"

727mm

28-5/8"

Summary of Contents for B-38030

Page 1: ...struction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Electronic automatic dryer sensor will pick up movement within 100mm 4 of the air outlet opening WARNING In the fixed wiring must be incorporated a disconnection device Dryer must be gr...

Page 2: ...equired by local electrical code 3 31mm dia No 12 wire or larger 2 Wiring Instructions a This appliance is intended for connection to fixed wiring b A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules c Check that the electrical rating shown on the dryer rating label is compatible with the electrical supply d WARNING THIS PRODUCT MU...

Page 3: ...gher RH may be allowed at lower temperatures Measures shall be taken by the Purchaser to avoid the harmful effects of occasional condensation 3 The equipment will operate correctly up to 2000m 6 560ft above mean sea level 4 The equipment will operate in a normal office type Pollution Degree 2 environment 5 The mains supplies in this equipment are designed to work at 10 voltage fluctuation of the m...

Page 4: ...der Die Reinigung und Instandhaltung durch Kinder darf nicht unbeaufsichtigt erfolgen Der elektronische Sensor des automatischen Trockners erfasst Bewegungen innerhalb eines Bereichs von 100 mm von der Luftaustrittsöffnung WARNUNG In der festverlegten Stromversorgung muss eine Trennvorrichtung vorgesehen sein Der Trockner muss geerdet werden SICHERHEITSWARNUNG Installation und Verdrahtung müssen g...

Page 5: ...en die elektrischen Leitungen von der nächstgelegenen Verteilertafel bis zur Grundplatte des Trockners verlegen ELEKTRISCHER ANSCHLUSS DES HÄNDETROCKNERS Die Einlassöffnungen für die Stromversorgung befinden sich auf der Gehäuserückseite in der unteren rechten Ecke der Trockner Montageplatte und auf der rechten Gehäuseseite Das Versorgungskabel wird mithilfe einer Leitungsführung durch eine dieser...

Page 6: ...leche sind stromführend Vor der Durchführung von Wartungs oder Instandhaltungsmaßnahmen am Trockner die Stromversorgung ausschalten Der Trockner darf nur mit angebrachter Abdeckung betrieben werden 1 Stromversorgung einschalten 2 Die Hände innerhalb eines Bereichs von 100 mm unter der Luftaustrittsöffnung positionieren 3 Bei Auftreten einer Störung die Stromversorgung unterbrechen und einen qualif...

Page 7: ...dos Los niños no pueden jugar con la unidad La limpieza y mantenimiento no se efectuará por niños sin supervisión El sensor electrónico automático percibe movimiento dentro de 100mm 4 de la salida de aire ADVERTENCIA Se debe colocar un interruptor en el cableado fijo de la pared El secador debe tener una conexión a tierra ADVERTENCIA DE SEGURIDAD La instalación y el cableado deben cumplir con las ...

Page 8: ...es CONEXIÓN ELÉCTRICA DEL SECADOR DE MANOS Los orificios de entrada para el suministro eléctrico se encuentran en la parte posterior del gabinete en la esquina inferior derecha de la base de montaje del secador y en el lado derecho del gabinete Los cables que suministran electricidad al gabinete deben contar con una mayor cantidad de material aislante El cable de alimentación en una de estas ubica...

Page 9: ...tro eléctrico antes de realizar cualquier mantenimiento o servicio al secador El secador no debe utilizarse a menos que la tapa esté en su lugar El suminstro eléctrico debe estar apagado a menos que la cubierta del secador esté colocada 1 Encienda el suministro de energía eléctrica 2 Coloque las manos por debajo del conducto dentro de 100mm 4 de la salida de aire 3 Si se presenta una falla descone...

Reviews: