I01�High-voltage�Components
10.�REME
157
3-phase�high-voltage�connector�at�the�REME
Index
Explanation
1
Range�Extender�Electrical�Machine�Electronics
2
Bridge�for�high-voltage�interlock�loop
3
Screw�for�securing�the�high-voltage�connector�at�the�REME�(under�the�bridge)
4
Three-phase�high-voltage�connector
5
Screws�for�securing�the�high-voltage�connector�at�the�REME
Two�of�the�three�screws�are�accessible�and�can�be�easily�slackened.�To�slacken�the�third�screw�the
bridge�of�the�high-voltage�interlock�loop�must�be�removed�first.�Only�then�is�the�third�screw�visible�and
it�can�be�slackened.�Separating�the�bridge�of�the�high-voltage�interlock�loop�causes�the�high-voltage
system�to�shut�down.