I01�High-voltage�Components
2.�Important�Notes
10
Index
Explanation
1
Electrical�contact�for�shielding
2
Electrical�contact�for�high-voltage�cable
3
Contact�protection
4
Mechanical�locking
5
High-voltage�interlock�loop�connector/bridge
2.3.2.�Removing�the�round�high-voltage�connector
The�procedure�described�here�applies�for�removing�the�round�high-voltage�connector�in�the�I01.
The�following�graphics�show�the�procedure�using�the�example�of�the�high-voltage�connection�at�the
electrical�machine�electronics,�at�which�the�high-voltage�cable�is�connected�for�the�electric�heating.