BMS EASY-CHECK FN Operational Manual Download Page 3

Operation 

EASY- CHECK FN 

Manual 

    Rev:00                                                           

 3  / 10

 

 

 

 

 

 

 

 

 

 

 

 

 

Introduction 

Congratulation ! You really made a good choice to decide for 

 
Easy-Check FN

because this device is not only designed and manufactured according 

to the latest level of technology, but also is extremely comfortable and easy to operate. 
We tried our best to write this manual as clear and short as possible. For any further in-
formation you may need, please contact our Service Department. Our technicians are al-
ways ready to help you. 

 
What can you measure with EASY-CHECK FN ? 
On iron and steel (FE) all non-magnetic coatings, such as varnish, paint, plastics, 
enamel, rubber, ceramics and galvanization (except niquel) up to 5,0 mm. 
On non-ferrous metals (aluminium, brass, bronze, zinc, lead, copper and non-
magnetic steel) all non-conductive coatings, such as varnish, paint, plastics, rubber 
and anodizing up to 2,5 mm. 
And in addition you can also measure paint coatings on zinc plated steel without 
considering the zinc thickness. 
In addition EASY-CHECK FN includes the following features 

 

  Store up to 1000 readings in the data memory 

 Display 

statistics 

  Transfer all readings and statistics to a printer or computer by means of the  

interface, or just 

  Transfer the data by RADIO. 

All these functions can be performed with the red key. 

 

And This Is Really Unique 

The device recognizes by itself on which base material the measurement is taken, whether 
on steel (FE) or on non-ferrous metal (NFE) and displays the symbol with each reading. 
EASY-CHECK FN can measure up to 80 hours with only one 1.5V Mignon battery. 
Worldwide the only device with a swinging measuring probe allowing to measure inside 
pipes and in other inaccessible places. 

 
Short  Instructions 

To make it as easy as possible for you and to be able to start taking measurements imme-
diately, we have already calibrated the device. 
 
You receive the instrument ready for operation and do not need to perform any ad-
justments. 
 
You just switch on the device with the red key. In the display  
appears <on>. 
 
That´s all  and now you can start taking measurements. 

 

 
 
 
 
 
 

Summary of Contents for EASY-CHECK FN

Page 1: ...NAL MANUAL Bms Bulut Makina Sanayi Ve Ticaret Ltd Şti İkitelli Organize Sanayi Bölgesi Dolapdere Sanayi Sitesi Ada 4 No 7 9 İkitelli İSTANBUL TÜRKİYE Phone 90 212 671 02 24 671 02 25 Fax 90 212 671 02 26 web www bulutmak com e mail bms bulutmak com ...

Page 2: ...IcL Clear the last reading 5 cLr Clear the whole Data Memory 5 nFE Base material recognition 5 Un Change unit of measurement µm mils 5 rES Resolution 6 Calibration 6 General Remarks 7 Exchange Of The Battery 7 Charge The 1 2v Rechargeable Battery With The Line Charging Unit 7 Technical Data 8 Optional Accessories 8 Software Incl Operation Instructions 8 Radio Control 9 Data Printer Mega Print 9 Da...

Page 3: ...ed steel without considering the zinc thickness In addition EASY CHECK FN includes the following features Store up to 1000 readings in the data memory Display statistics Transfer all readings and statistics to a printer or computer by means of the interface or just Transfer the data by RADIO All these functions can be performed with the red key And This Is Really Unique The device recognizes by it...

Page 4: ...Modes Sto Store readings in the Data Memory To store readings in the memory for further evaluation press the key until Sto is dis played Now release the key and wait until on is flashing Confirm by pressing the key again The data memory is activated and all subsequent measurements will be stored The sym bol STORE is displayed to make evident that the memory is switched on Capacity of the data memo...

Page 5: ...nt and the zinc coating together because it is not able to recognize the thin zinc coating as non ferrous base ma terial nFE To measure only the paint coating on the zinc plating the device must be switched over to the nFE mode To avoid wrong measurements the following requirements should be met The zinc plating should have a thickness of at least 20 µm The zero adjustment should be performed on a...

Page 6: ...e device on 2 Set the device with the probe on the base plate FE blue and press the key for about 2 sec until 0 0 is displayed stable Then release the key and zero setting is per formed and confirmed by a beep signal 3 Take off the device the foil value entered previously is flashing 4 To enter the value of the shim press the key as long as the value scrolls up Pressing the key shortly the value g...

Page 7: ...nged by a new one When the voltage of the battery is less than 0 8 V the device switches off by itself Please insert only leak proved batteries Charge The 1 2v Rechargeable Battery With The Line Charging Unit As soon as the symbol BAT is flashing the rechargeable 1 2V Mignon battery must be charged Important Before inserting the charging connector into the interface plug of EASY CHECK FN the devic...

Page 8: ... MEAN STD DEV Power Supply 1 5V Mignon battery 1 2V rechargeable battery with charger available Recording Data on steel FE one long beep on non ferrous metals NFE two short beeps Measuring Probe swinging by 90 Dimensions 108 x 48 x 38 mm Weight approx 100 g Interface serial RS 232 C 5 V TTL level Baudrate Printer PC 1200 baud Data Stop bits Printer PC 7 2 Warranty Indication unit 12 months Measuri...

Page 9: ...t in NiCad battery must be charged The built in NiCad battery is charged with the charging unit supplied with the printer The cable of the charging unit is connected at the right hand socket of MEGA PRINT The charging time should be at least 4 hours Operating Instructions 1 The operation of MEGA PRINT together with the Coating Thickness Meter EASY CHECK FN is explained in the operating instruction...

Page 10: ...Insert a new paper roll Open the lid Insert the paper roll Pull out the end of the paper Close the lid Operation EASY CHECK FN Manual Rev 00 10 10 ...

Reviews: