BMS EASY-CHECK FN Operational Manual Download Page 2

Operation 

EASY- CHECK FN 

Manual 

    Rev:00                                                           

 2  / 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Introduction ...............................................................................................................3 

Easy-Check FN ........................................................................................................3 

And This Is Really Unique ............................................................................................3 
Short  Instructions ......................................................................................................3 

Function Modes ..........................................................................................................4 
Operation Of The Function Modes ................................................................................4 

<Sto> Store readings in the Data Memory.................................................................4 

<StA> Display Statistics ...........................................................................................4 
<Prn> Print or activate the RADIO CONTROL function................................................5 

<IcL> Clear the last reading.....................................................................................5 
<cLr> Clear the whole Data Memory.........................................................................5 

<nFE> Base material recognition..............................................................................5 
<Un> Change unit of measurement (µm / mils).........................................................5 

<rES> Resolution ....................................................................................................6 

Calibration..................................................................................................................6 
General Remarks ........................................................................................................7 

Exchange Of The Battery..........................................................................................7 

Charge The 1.2v Rechargeable Battery With The Line-Charging Unit ...............................7 

Technical Data............................................................................................................8 

Optional Accessories ...................................................................................................8 

Software Incl. Operation Instructions ........................................................................8 

Radio-Control .............................................................................................................9 

Data Printer Mega-Print............................................................................................9 

Data Printer  Mega-Print ..............................................................................................9 

Technical Data: .......................................................................................................9 
Operating Instructions .............................................................................................9 

Insert a new paper roll........................................................................................... 10 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

 
 
 

Summary of Contents for EASY-CHECK FN

Page 1: ...NAL MANUAL Bms Bulut Makina Sanayi Ve Ticaret Ltd Şti İkitelli Organize Sanayi Bölgesi Dolapdere Sanayi Sitesi Ada 4 No 7 9 İkitelli İSTANBUL TÜRKİYE Phone 90 212 671 02 24 671 02 25 Fax 90 212 671 02 26 web www bulutmak com e mail bms bulutmak com ...

Page 2: ...IcL Clear the last reading 5 cLr Clear the whole Data Memory 5 nFE Base material recognition 5 Un Change unit of measurement µm mils 5 rES Resolution 6 Calibration 6 General Remarks 7 Exchange Of The Battery 7 Charge The 1 2v Rechargeable Battery With The Line Charging Unit 7 Technical Data 8 Optional Accessories 8 Software Incl Operation Instructions 8 Radio Control 9 Data Printer Mega Print 9 Da...

Page 3: ...ed steel without considering the zinc thickness In addition EASY CHECK FN includes the following features Store up to 1000 readings in the data memory Display statistics Transfer all readings and statistics to a printer or computer by means of the interface or just Transfer the data by RADIO All these functions can be performed with the red key And This Is Really Unique The device recognizes by it...

Page 4: ...Modes Sto Store readings in the Data Memory To store readings in the memory for further evaluation press the key until Sto is dis played Now release the key and wait until on is flashing Confirm by pressing the key again The data memory is activated and all subsequent measurements will be stored The sym bol STORE is displayed to make evident that the memory is switched on Capacity of the data memo...

Page 5: ...nt and the zinc coating together because it is not able to recognize the thin zinc coating as non ferrous base ma terial nFE To measure only the paint coating on the zinc plating the device must be switched over to the nFE mode To avoid wrong measurements the following requirements should be met The zinc plating should have a thickness of at least 20 µm The zero adjustment should be performed on a...

Page 6: ...e device on 2 Set the device with the probe on the base plate FE blue and press the key for about 2 sec until 0 0 is displayed stable Then release the key and zero setting is per formed and confirmed by a beep signal 3 Take off the device the foil value entered previously is flashing 4 To enter the value of the shim press the key as long as the value scrolls up Pressing the key shortly the value g...

Page 7: ...nged by a new one When the voltage of the battery is less than 0 8 V the device switches off by itself Please insert only leak proved batteries Charge The 1 2v Rechargeable Battery With The Line Charging Unit As soon as the symbol BAT is flashing the rechargeable 1 2V Mignon battery must be charged Important Before inserting the charging connector into the interface plug of EASY CHECK FN the devic...

Page 8: ... MEAN STD DEV Power Supply 1 5V Mignon battery 1 2V rechargeable battery with charger available Recording Data on steel FE one long beep on non ferrous metals NFE two short beeps Measuring Probe swinging by 90 Dimensions 108 x 48 x 38 mm Weight approx 100 g Interface serial RS 232 C 5 V TTL level Baudrate Printer PC 1200 baud Data Stop bits Printer PC 7 2 Warranty Indication unit 12 months Measuri...

Page 9: ...t in NiCad battery must be charged The built in NiCad battery is charged with the charging unit supplied with the printer The cable of the charging unit is connected at the right hand socket of MEGA PRINT The charging time should be at least 4 hours Operating Instructions 1 The operation of MEGA PRINT together with the Coating Thickness Meter EASY CHECK FN is explained in the operating instruction...

Page 10: ...Insert a new paper roll Open the lid Insert the paper roll Pull out the end of the paper Close the lid Operation EASY CHECK FN Manual Rev 00 10 10 ...

Reviews: