![background image](http://html.mh-extra.com/html/bmpro/controlnode/controlnode_owners-manual_2779840028.webp)
28
BATTERY CHARGING MANAGEMENT ALGORITHM
The following describes the Battery Charging Management Algorithm used by
the J35 when charging the caravan battery from a mains power source. The J35
will operate as described when the caravan loads are connected directly to the
J35 and not the caravan battery.
Battery Capacity
Soft Start
Boost + Bulk-Absorption
Float
≤ 100AH
6 Hours
5 Hours
6 Hours
150AH
6 Hours
7.5 Hours
6 Hours
200AH
6 Hours
10 Hours
6 Hours
250AH
6 Hours
12.5 Hours
6 Hours
≥ 300AH
6 Hours
15 Hours
6 Hours
Table 7:
Timeout for each charging mode, based on battery capacity
Figure 5:
J35 Battery Charging Management Algorithm